Magellan & Spectra SP • Installation Guide
One-Touch Arming
(Not to be used with UL installations)
Section
[703]
: Options
[1]
to
[3]
Option
[1]
ON = Press & hold the
[
ARM
]
key for One-touch Regular Arming.
Option
[2]
ON = Press & hold the
[
STAY
]
key for One-touch Stay Arming.
Option
[3]
ON = Press & hold the
[
SLEEP
]
key for One-touch Sleep Arming.
The One-touch arming features allow users to arm the system without having to enter any access codes. To arm the system, press and hold the appropriate key (see
above) for approximately 3 seconds. If the system is partitioned, you must also press the key corresponding to the partition you wish to arm.
One-Touch Bypass Programming
(Not to be used with UL installations)
Section
[703]
: Options
[4]
Option
[4]
ON = Press & hold the
[
BYP
]
key for One-touch Bypass Programming.
Bypass programming allows users to program the alarm system to ignore (deactivate) specified zones the next time the system is armed. Press and hold the
[
BYP
]
key for three seconds to access bypass programming mode.
Exit Delay
Section
[745]
= Partition 1,
[746]
= Partition 2
001 to 255 seconds, Default = 60 seconds,
Maximum 60 seconds for UL Listed systems
After entering the required arming sequence (i.e. user access code, etc.), the exit delay parameter determines the amount of time a user has to leave the protected
area before the control panel arms the partition. The exit delay applies to all zones in the selected partition. When enabled, the keypad will beep once every second
during the exit delay and will beep rapidly during the final 10 seconds of the exit delay.
Beep On Exit Delay
Section
[704]
: Arming/Disarming Options
Option
[6]
OFF= Beep on Exit Delay Disabled
Option
[6]
ON= Beep on Exit Delay Enabled (default)
Bell Squawk On Arm/Disarm with Keypad
Section
[704]
: Arming/Disarming Options
Option
[5]
OFF= Bell Squawk on Arm/Disarm Disabled (default)
Option
[5]
ON= Bell Squawk on Arm/Disarm Enabled
When this feature is enabled, the bell or siren will squawk once upon arming and twice upon disarming via the keypad.
Bell Squawk On Arm/Disarm with Remote Control
Section
[704]
: Arming/Disarming Options
Option
[4]
OFF= Bell Squawk on Arm/Disarm with Remote Control Disabled (default)
Option
[4]
ON= Bell Squawk on Arm/Disarm with Remote Control Enabled
When this feature is enabled, the bell or siren will squawk once upon arming with a remote control and twice upon disarming with a remote control. Must be
enabled for UL installations.
No Exit Delay When Arming with Remote Control
Section
[704]
: Arming/Disarming Options
Option
[8]
OFF= Provides Exit Delay When Arming with a Remote Control (default)
Option
[8]
ON= No Exit Delay When Arming with a Remote Control
When the option is enabled, the panel cancels the exit delay (arms instantly) when a partition is armed with a remote control. When disabled, the exit delay timer
will start when a partition is armed with a remote control.
No Exit Delay Beeps and No Bell Squawk When Stay/Sleep Arming
Section
[704]
: Arming/Disarming Options
Option
[7]
OFF= No Exit Delay Beeps and No Bell Squawk When Stay/Sleep Arming Disabled
Option
[7]
ON= No Exit Delay Beeps and No Bell Squawk When Stay/Sleep Arming Enabled (default)
With this feature enabled, the control panel will prevent the bell or siren from squawking and the keypads from beeping during the exit delay, whenever a partition
is Stay/Sleep armed.
Exit Delay Termination
Section
[700]
: Arming/Disarming Options
Option
[6]
OFF= Exit Delay Termination (Disabled)
Option
[6]
ON= Exit Delay Termination Enabled (default)
When option [6] is enabled (ON), the panel will reduce the Exit Delay to 10 seconds when an Entry Delay zone is opened and closed during the Exit Delay.
Example:
15 seconds into a 45 second Exit Delay, an Entry Delay zone opens and closes. The remaining 30 seconds is reduced to 10 seconds.
Fast Exit
When the system is already Stay or Sleep armed: This feature will allow you to exit and keep the system armed. Press and hold the
[
OFF
]
key for 3 seconds to start the
exit delay. After the exit delay has elapsed, the system will switch to its previous arming mode.
Содержание Magellan MG5050E
Страница 2: ......
Страница 16: ...16 Magellan Spectra SP Installation Guide SP5500 8x10 SP6000 11x11 SP7000 11x11...
Страница 25: ...Magellan Spectra SP Installation Guide 25 Russian Special Characters Catalogue Russian Keypad Letter Assignment...
Страница 67: ......