Magellan & Spectra SP • Installation Guide
Tamper Supervision on Panel (MG5075 only)
Section
[700]
: Supervision Options
Option
[8]
OFF= Panel tamper supervision disabled
Option
[8]
ON= Panel tamper supervision enabled (default)
When the control panel detects a tamper, the control panel can generate an alarm or trouble, unless the Tamper Supervision is disabled.
Keypad Panic Options
Section
[702]
: General Options
Option
[1]
OFF= Panic 1 Disabled (default)
Option
[1]
ON = Panic 1 Enabled
Pressing the
[1]
and
[3]
keys simultaneously on the keypad for 3 seconds will generate a silent or audible alarm as defined by option
[4]
.
Option
[2]
OFF= Panic 2 Disabled (default)
Option
[2]
ON = Panic 2 Enabled
Pressing the
[4]
and
[6]
keys simultaneously on the keypad for 3 seconds will generate a silent or audible alarm as defined by option
[5]
.
Option
[3]
OFF=
Panic 3 Disabled (default)
Option
[3]
ON =
Panic 3 Enabled
Pressing the
[7]
and
[9]
keys simultaneously on the keypad for 3 seconds will generate a silent or audible alarm as defined by option
[6]
.
Option
[4]
OFF= Panic 1 is Silent (default)
Option
[4]
ON = Panic 1 is Audible
Option
[5]
OFF= Panic 2 is Silent (default)
Option
[5]
ON = Panic 2 is Audible
Option
[6]
OFF= Panic 3 is Silent (default)
Option
[6]
ON =
Panic 3 is Audible
Silent alarm
:
The control panel emits a confirmation beep and transmits the appropriate Panic report code if programmed in section
[863]
. The control panel will not enable the
keypad buzzers or the control panel’s
BELL
output (no audible alarm).
Audible alarm
:
Same as silent alarm, except the keypad buzzers and the
BELL
output will activate until a user cancels the alarm (disarms) with a valid user access code or when the
Bell Cut-Off Timer elapses (See “Bell Cut-Off Timer” on page 47).
Whether the system is partitioned or not, the control panel will report all panic alarms to partition 1.
Panic Lockout Timer
Section
[718]
When a panic alarm is activated, the control panel can ignore the disarm signal from a remote control for a specified period. This prevents an aggressor from
disarming the system by remote control during a panic situation. In section
[718]
enter a 3-digit value (000 to 255, 000 = disabled) representing the number of
seconds that the remote controls will be locked out of the system.
Flex-Instant Delay
Section
[720]
The Flex-Instant Delay is used to prevent false alarms when the premises is Stay/Sleep armed. In section
[720]
enter a 3-digit value (000 to 255, 000 = disabled)
representing the number of seconds that the panel will delay an alarm allowing you to disarm the system (default 15 seconds).
Содержание Magellan MG5050E
Страница 2: ......
Страница 16: ...16 Magellan Spectra SP Installation Guide SP5500 8x10 SP6000 11x11 SP7000 11x11...
Страница 25: ...Magellan Spectra SP Installation Guide 25 Russian Special Characters Catalogue Russian Keypad Letter Assignment...
Страница 67: ......