10
EVOHD+ Installation Guide
Figure 5: EVOHD+ Control Panel Wiring Diagram
40VA transformer strongly recommended.
This equipment must be installed and maintained by qualified service personnel only.
The Digiplex bus supports a maximum of 254 modules. Although external power supplies can be used to provide power to modules connected far
from the control panel, the total distance of all runs of wire combined cannot exceed 914m (3000ft). For example, if ten runs of wire measuring
305m (1000ft) each are connected to the control panel, the total distance would be 3048m (10,000ft), which exceeds the system's capacity.
The sum of the current drawn from the
BELL
and
AUX
must be limited to 2.5A. Exceeding this limit will overload the panel power supply
and lead to complete system shutdown.
1 Four-pin connector can be used for quick installation of a keypad
2
LEDs
Charge LED:
Charging and battery test LED
AUX LED:
ON = Aux present; OFF = Aux off
Status LED:
•
Flash once every second: Normal
•
Flashes ON 1 sec. and OFF 1 sec.: Any trouble
•
Always ON: Panel is using phone line
•
Fast flash 6 seconds after power: Installer lock enabled
3 Panel reset
4 EBUS and Dialer used with:
•
VDMP3 Plug-In Voice Module for voice reporting
•
PCS Series Communicator Module
5 Serial 1: Used as the primary reporting channel for connecting the IP
Module/PCS Module
6 Serial 2: Used as a backup reporting channel for connecting the IP
Module/PCS Module
7 Zone Input
8 PGM output connector
9 The
BELL
output will shutdown if the current exceeds 3A
10 AC Power connections
11 Backup Battery connections
12 AWG#14 single conductor solid copper wire
13 Ground clamp
14 Cold water pipe grounding
15 To ground
16 Keypad’s zone configuration
17 Zone connections, if EOL is enabled, see section
[706]
option 2
18 To connect additional wiring to auxiliary power, use the red (
+
) and black
(
-
) keypad connectors; auxiliary power will shut down if current exceeds
1.1A; if the auxiliary output is overloaded and shuts down, you must
disconnect all loads from the output for at least 10 sec. before
reconnecting any load back to the auxiliary output
To provide maximum
lightning protection we
strongly recommend having
separate earth connections
for the dialer and zone
ground terminals.
Enter section [3000] to
unlock your EVOHD+
panel serial ports for use
with third-party devices
using a TM70/TM50,
K641+, K656, or K641R
keypad.