EVOHD+ Installation Guide
37
Police Code Timer
(default =
000
) If an alarm condition occurs on a zone, the control panel generates an alarm and triggers the Police Code Timer. The Police Code programmed in
[3934]
will only be sent if one of the following conditions occurs during the delay:
1.
An alarm occurs on another zone.
2.
The zone in alarm restores and reoccurs.
Key in the desired 3-digit delay value (001 to 255 minutes, 000 = disabled) into the section corresponding to the desired partition:
on page 25 to set it up so that a police code is only generated on Zone Crossing.
Tamper Recognition Options
S
ECTION
[3034]: O
PTIONS
[5]
AND
[6]
When the control panel detects a tamper or wire fault on a zone or on an expansion module, the control panel can generate an alarm and/or trouble, as shown in
the table below.
Partition 1:
[3118]
Partition 3:
[3318]
Partition 5:
[3518]
Partition 7:
[3718]
Partition 2:
[3218]
Partition 4:
[3418]
Partition 6:
[3618]
Partition 8:
[3818]
[5] [6]
Description
OFF OFF
Disabled (default):
Displays zone open on the keypads, but will not generate an alarm or trouble.
Not permitted on UL systems.
OFF ON
Generates Trouble Only (when armed or disarmed):
The control panel displays
Zone Fault
in the Trouble Display and transmits the
defined report code (see
ON OFF
When disarmed: Generates Trouble Only
The control panel displays
Zone Fault
in the Trouble Display and transmits the
defined report code (see
When armed: Follows Zone Alarm Type
The control panel follows the zone’s alarm type (see
ON
ON
When disarmed: Generates Audible Alarm
The control panel displays
Zone Fault
in the Trouble Display, transmits the
defined report code (see
on page 40), and generates an audible
alarm.
When armed: Follows Zone Alarm Type
The control panel follows the zone’s alarm type (see