26
EVOHD+ Installation Guide
Input Speed
(001 to 255 X 30msec
,
default =
600ms
)
The Input Speed defines how quickly the control panel responds to an open zone detected on any hardwired input terminal (does not apply to addressable motion
detectors and door contacts). Set the Input Speed (001 to 255 X 30ms, default =
600ms
):
EOL on Hardwire Zones
S
ECTION
[3033]: O
PTION
[7]
(default =
disabled
) If detection devices connected to hardwired input terminals use 1k
end of line resistors, enable option
[7]
in section
[3033]
. For details on
on page 16. For more information on EOL options, please refer to
the EVOHD+ programming guide.
Selectable Input Resistor
S
ECTION
[0402]
(default =
disabled
) T
o select a different value for EOL resistor, please refer to the EVOHD+ Programming Guide.
Keypad Numbering
S
ECTIONS
[2801]
TO
[2832]
Keypad Numbering identifies the keypad in the event buffer. The keypad is assigned to a Keypad Number from 1 to 32 through the keypad's serial number in
sections
[2801]
to
[2832]
.
[0961]
Input 01
[0973]
Input 13 (ATZ of Input 01)
[0962]
Input 02
[0974]
Input 14 (ATZ of Input 02)
[0963]
Input 03
[0975]
Input 15 (ATZ of Input 03)
[0964]
Input 04
[0976]
Input 16 (ATZ of Input 04)
[0965]
Input 05
[0977]
Input 13 (ATZ of Input 01)
[0966]
Input 06
[0978]
Input 14 (ATZ of Input 02)
[0967]
Input 07
[0979]
Input 15 (ATZ of Input 03)
[0968]
Input 08
[0980]
Input 16 (ATZ of Input 04)
Содержание EVOHD+
Страница 1: ...EVOHD Installation Guide High Security Access System...
Страница 86: ......