64
EVOHD+ Installation Guide
Access Control: System Features
For details on connecting Access Control devices, refer to the “Digiplex Access Control Module Reference & Installation Manual”.
Figure 19: Typical Access Control Installation
Persons authorized to access the protected area are issued cards assigned to user access codes programmed with an Access Level (see section ) and a Schedule (see
section ). The control panel determines whether or not to unlock the door depending on the card’s schedule and access.
Common Access Control Terms
Access Alarm
: A warning generated by the reader if an Access Door is open past the programmed time or if it was opened without the proper signal. This event is
logged in the Event Buffer, but cannot be reported.
Access Card
: A tag assigned to a user access code used to identify the user to the Access Control system.
Access Denied
: The system preventing access through an Access Door.
Access Granted
: The system granting access through a protected door.
Burglar Alarm
: A warning sent to the control panel if an armed zone in the EVOHD+ security system has been breached. This event is logged in the Event Buffer and
can be reported to a monitoring station.
Door Left Open
: Each Access Door is programmed with a period of time it is allowed to stay open. An Access Alarm will be triggered after that period.
Forced Door
: An Access Door was opened without an “Access Granted” or “Request for Exit” signal, a silent or audible Access Alarm can be triggered.
Reader
: An Access Control device (R910) located near an Access Door that sends the information from an Access Card to the control panel.
Request for Exit
: When a REX device (Paradoor 460) detects movement, it sends a request-for-exit signal to the panel.
Valid Card
: An Access Card presented to a reader during its assigned Schedule and within its assigned Access Level.
Programming Overview
The following is the
MINIMUM
required to program Access Control:
1.
Enable Access Control in section
[3038]
option
[1]
.
2.
Assign the Doors in sections
[2201]
to
[2232]
.
3.
Create the Access Levels in sections
[2601]
to
[2615]
.
4.
Create the Schedules in sections
[2401]
to
[2432]
.
5.
Set the Holidays in sections
[2701]
to
[2712]
.
6.
Program user access codes (see section on page 60).
7.
Program the Access Control Modules.
Enable Access Control
S
ECTION
[3038]: O
PTION
[1]
(default =
disabled
) Enable to activate Access Control.
Door Numbering
S
ECTIONS
[2201]
TO
[2232]
Each door monitored and controlled requires an Access Control Module (ACM12) or an access keypad. The keypad or module is assigned to the door in sections
[2201]
to
[2232]. EVOHD+ supports up to 32 Doors.
1 = Request for Exit Device (Paradoor)
2 = Door Contact
3 = Reader (R910 or R915) on
other side of the wall
4 = Access Control Module (ACM12)
5 = Locking Device
6 = Control Panel (