80
EVOHD+ Installation Guide
Display Entry Delay Timer
S
ECTION
[003]: O
PTION
[3]
Option
[3]
OFF=Will not display the Entry Delay Timer (default)
Option
[3]
ON=LCD screen will display Entry Delay Timer
Confidential Mode
S
ECTION
[003]: O
PTIONS
[4]
AND
[5]
Section [003]:
Option
[4]
OFF=Normal Mode (default)
Option
[4]
ON=Confidential Mode
Option
[5]
OFF=LCD screen activated by entering an access code (default)
Option
[5]
ON=LCD screen activated by pressing a button
Confidential Mode Timer
S
ECTION
[007]
Section
[007]
determines the amount of time without action before the keypad enters Confidential Mode. The Confidential Mode Timer can be set from 005
seconds to 255 seconds.
Default: 120 secs.
Time Display Option
S
ECTION
[003]: O
PTION
[8]
Option
[8]
OFF=Date displayed as yy/mm/dd (default)
Option
[8]
ON=Date displayed as dd/mm/yy
Muting
S
ECTION
[004]: O
PTION
[1]
Option
[1]
OFF=Audible sounds (default)
Option
[1]
ON=Mute
Beep on Exit Delay
S
ECTION
[004]: O
PTION
[2]
Option
[2]
OFF=Exit Delay beep disabled
Option
[2]
ON=Exit Delay beep enabled (default)
Chime on Zone Closure
S
ECTION
[004]: O
PTION
[4]
Option
[4]
OFF=Chime on Zone Closure disabled (default)
Option
[4]
ON=Chime on Zone Closure enabled
Beep on Trouble
S
ECTION
[005]: O
PTIONS
[1]
TO
[4]
Option
[1]
OFF=Beep disabled: System Troubles and Clock Loss
Option
[1]
ON=Beep enabled: System Troubles and Clock Loss
Option
[2]
OFF=Beep disabled: Communicator Troubles
Option
[2]
ON=Beep enabled: Communicator Troubles
Option
[3]
OFF=Beep disabled: Module and Digiplex bus Troubles
Option
[3]
ON=Beep enabled: Module and Digiplex bus Troubles
Option
[4]
OFF=Beep disabled: all Zone Troubles
Option
[4]
ON=Beep enabled: all Zone Troubles
Keypad Tamper Enable
S
ECTION
[006]: O
PTION
[5]
Option
[5]
OFF=Keypad's tamper is disabled (default)
Option
[5]
ON=Keypad's tamper is enabled
Time Format
S
ECTION
[005]: O
PTION
[7]
Option
[7]
OFF=Time uses the International time format (default).
Option
[7]
ON=Time uses the US time format.
Digiplex bus
Voltmeter
1.
From Normal Mode press and hold the
[0]
key.
2.
Enter the
[
INSTALLER
CODE
]
(by default 000000).
3.
Press
[
ACC
].
NOTE:
The voltage may drop during the control panel battery test.