22
EVOHD+ Installation Guide
Entry Delays 1 and 2
SECTION
[0400]: F
IRST
DIGIT
= 1
AND
2
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= 1
AND
2
(default Entry Delay 1=
030
, Entry Delay 2 =
060
) A zone defined as Entry Delay 1 follows the Entry Delay 1 Timer of its assigned partition. A zone defined as Entry
Delay 2 follows the Entry Delay 2 Timer of its assigned partition. Each partition includes two Entry Delay Timers. To program an Entry Delay Timer, key in the desired
3-digit delay value (001 to 255 seconds) into the corresponding section.
NOTE:
These are the same timers used for Stay Delay zones.
Follow Zones
SECTION
[0400]: F
IRST
DIGIT
= 3
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= 3
The control panel waits until the end of the Entry Delay before generating an alarm if an Entry Delay zone opens before the Follow zone.
Instant Zones
SECTION
[0400]: F
IRST
DIGIT
= 4
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= 4
When an armed Instant zone opens, the control panel immediately generates an alarm.
24Hr Buzzer Zones
SECTION
[0400]: F
IRST
DIGIT
= 5
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= 5
Whenever a 24Hr Buzzer zone opens, the control panel activates the keypad buzzer to indicate that the zone was breached. The control panel will report the alarm,
but will not enable the bell/siren output. Enter any valid access code on the keypad to stop the buzzer.
NOTE:
The keypads must be assigned to the same partition as the 24Hr Buzzer zone or the buzzer will not activate. UL Note: Not to be used for perimeter protection.
24Hr Burglary Zones
SECTION
[0400]: F
IRST
DIGIT
= 6
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= 6
When a 24Hr Burglary zone opens, the control panel will immediately generate a burglary alarm.
24Hr Hold-up Zones
SECTION
[0400]: F
IRST
DIGIT
= 7
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= 7
When a 24Hr Hold-up zone opens, the control panel will immediately generate an alarm.
NOTE:
The SIA FSK reporting format includes specific codes to identify the alarm as a Hold-up, Gas, Heat, Water, or Freeze Alarm.
24Hr Gas Zones*
SECTION
[0400]: F
IRST
DIGIT
= 8
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= 8
When a 24Hr Gas zone opens, the control panel will immediately generate an alarm.
24Hr Heat Zones**
SECTION
[0400]: F
IRST
DIGIT
= 9
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= 9
When a 24Hr Heat zone opens, the control panel will immediately generate an alarm.
** UL Note:
UL Listed compatible devices must be used for UL systems. For UL Listed systems, this type of zone should be programmed as a pulsing Fire alarm.
24Hr Water Zones*
SECTION
[0400]: F
IRST
DIGIT
= A
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= A
When a 24Hr Water zone opens, the control panel will immediately generate an alarm.
Partition 1
Entry Delay 1 Timer:
[3111]
Entry Delay 2 Timer:
[3112]
Partition 2
Entry Delay 1 Timer:
[3211]
Entry Delay 2 Timer:
[3212]
Partition 3
Entry Delay 1 Timer:
[3311]
Entry Delay 2 Timer:
[3312]
Partition 4
Entry Delay 1 Timer:
[3411]
Entry Delay 2 Timer:
[3412]
Partition 5
Entry Delay 1 Timer:
[3511]
Entry Delay 2 Timer:
[3512]
Partition 6
Entry Delay 1 Timer:
[3611]
Entry Delay 2 Timer:
[3612]
Partition 7
Entry Delay 1 Timer:
[3711]
Entry Delay 2 Timer:
[3712]
Partition 8
Entry Delay 1 Timer:
[3811]
Entry Delay 2 Timer:
[3812]
Содержание EVOHD+