158
159
Event function
The recorder will take an event action when any of the following events occur.
Terminal alarm:
An event when an alarm input signal is supplied from an external device such as a
door sensor to the alarm input terminal on the rear of the recorder.
Camera site alarm:
An event when an alarm (camera terminal alarm, etc.) is detected by a camera.
Command alarm:
An alarm when receiving an alarm from a PC, etc. via a network.
Face matching alarm*: Alarm issued when a face matches an already registered facial image.
* When the license of the additional business intelligence kit is registered
Note:
Operations such as registration of facial images, display of face matching results, and starting and stopping
•
the face matching function are not possible from a web browser, regardless of whether the recorder is set
up for use of this function. Refer to the Operating Instructions of the Additional Business Intelligence Kit for
further information about the setting conditions or restrictions of the face matching function.
Action to be taken upon an event occurrence
When the recorder recognizes an event, it will take an event action according to the set action mode.
Refer to the "Event action" (
☞
page 120) for further information about the event action and action mode.
The actions that can be set up and checked from a PC when an event occurs are described below.
Display the alarm message
A window that notifies of an event occurrence will be displayed.
Click the [OK] button or the [x] button to close the window. When several events occur at the same time, the
information for the event that occurred last will be displayed.
Display the alarm button
The [ALM] button will be displayed in the status dis-
play area. The alarm action will be canceled by click-
ing [ALM] button. (
☞
Page 159)
Display the error button
The [ERR] button will be displayed in the status dis-
play area. The error action will be canceled by click-
ing [ERR] button. (
☞
Page 159)
Send a mail that notifies of an event occurrence
A mail that notifies of the event occurrence with the
date & time of the event occurrence will be sent
(Alarm mail).
Up to 4 destination addresses for the alarm mail can
be registered.
Provide an alarm notification to a PC according to
the Panasonic alarm protocol setting
When an event or an error occurs, information about
the event/ error will automatically be notified to the
registered PC according to the "Panasonic alarm pro-
tocol" setting. To receive a notification and display
the contents, it is necessary to install the dedicated
software (option).
Refer to the "readme.txt" on the provided CD-ROM
about the dedicated software.