54
• Post-event recording
1 - 10 s (in 1-second interval)/20 s/30 s/1 - 10 min
(in 1-minute interval)/20 - 60 min (in 10-minutes
interval)
MANUAL:
Recording will continue while the external
switch is being held down.
CONTINUE:
Recording will not stop until the
[ALARM RESET] button is pressed.
Note:
When "MANUAL" is selected for "DURATION"
(recording duration), recording will be performed for
at least 8 seconds at an event occurrence as long as
the alarm is not canceled.
■
Measurement
It is possible to start calculation of maximum value of
recording rate/transmission rate (ips) that can be set for
"LIVE VIDEO", "MANUAL REC" and "EVENT REC" by
clicking this button.
Recording will stop for around 90 seconds due to the
calculation.
Notes:
• Do not change any settings while calculation.
• Recording, playback and live image transmission will
stop in the process of calculation. Other users who
have logged in to this unit will be forcibly logged out.
(They need to log in to this unit after the calculation
is complete.)
• Calculation result is indicated as a reference value.
It may come to a different result depending on the
status of the network environment.