47
Settings for emergency recording [Emergency REC]
Perform the settings for emergency recording such as the recording time or recording rate. Refer to the provided
operating instructions for further information about emergency recording.
Screenshot 1
Click the [Recording] button in the setup menu
(Advanced) and then click "Emergency REC". The
"Emergency REC" window will be displayed.
Step 1
Perform the settings for each item.
■
Recording Duration
Perform the settings for emergency recording such as
the recording time and recording actions.
The following are available for the recording time.
1 s - 10 s (in 1 second intervals)/20 s/30 s/1 min -
10 min (in 1 minute intervals)/20 min/30 min/40 min/
50 min/ 60 min
MANUAL:
Recording will continue while the external
switch is being held down.
CONTINUE:
Recording will not stop until the [ALARM
RESET] button is pressed.
Note:
When "MANUAL" is selected, recording will be per-
formed for at least 8 seconds.
■
Recording Rate
Perform the settings for emergency recording for each
camera channel such as the recording rate or image
quality.
The following are available for "Recording Rate". When
OFF is selected for a specified camera channel, images
from a camera channel set to OFF will not be recorded.
OFF/1 ips/2 ips/3 ips/5 ips/10 ips/15 ips/ALL
Note:
The available value differs depending on the select-
ed image compression method. The compression
method can be set on the "MODEL/COMPRES-
SION" setting of the setup menu ("Camera" – "NW
Camera Setup" – "MODEL/COMPRESSION").
Step 2
Click the [SET] button after completing the settings.
Important:
Recording will not be performed for around 4 sec-
onds just after the emergency recording.
Содержание WJ-ND300 Administrator Console