Perform the settings for site alarm [Site Alarm Setup]
Perform the settings relating to the site alarm such as the setting to validate or invalidate the original alarm from
cameras, the port number used for receiving the original alarm, and the event actions for each camera channel at an
original alarm occurrence.
Screenshot 1
Click "Event" on the setup menu (Advanced) and then
click "Site Alarm Setup" to display the "Site Alarm
Setup" window.
Step 1
Perform the settings for each item.
■
Site Alarm
Select "ON" or "OFF" whether to validate or invalidate
the site alarm.
ON:
Validates the site alarm.
OFF:
Invalidates the site alarm.
■
Port Number (from Camera)
Designate the port number to be used for receiving the
site alarm.
■
Site Alarm Setup
Perform the settings for the following items for each
camera channel.
[REC CAM]
Performs the settings for a camera channel currently
used for recording.
[PRESET]
Select the preset position (--, 1-16) to which the camera
will move at an alarm occurrence.
When "--" is selected, the camera will not move to the
preset position.
[Output Terminal]
Select the output terminal (--, TRM1-TRM16) that out-
puts alarm signals at an alarm occurrence. When "--" is
selected, alarm signals will not be output.
Step 2
Click the [SET] button after completing the settings.