18
■
Multiple System Domains with Single SX650 Switch Node
The following system includes two system domains. Each system domain has its own SX650 switch node. The sys-
tem domain has two WJ-SX650 matrix switchers. It contains a domain WJ-MPU955A CPU with the WJ-ASC960
upgrade software installed. Within the domain, a PC with WJ-ASC960 Admin Console software installed is required
to configure resources and operations within the domain. The two system domains can work independently as
standalone systems. The sample Local database – 01=multi650_1.adm, 02=multi650_2.adm -and sys.ini file –
01A=sys.ini, 02A=sys.ini -for Administration Console are provided on the CD-ROM. The sample Global database -
#=multi650.gdm - for Admin is provided on the CD-ROM. Also refer to Appendix 4.
Cam1-1
Cam1-4
Cam1-2
Cam1-7
Cam1-3
Cam1-5
Cam1-6
Cam1-8
Cam2-1
Cam2-4
Cam2-2
Cam2-7
Cam2-3
Cam2-5
Cam2-6
Cam2-8
3
C
1
2
B
1
2
3
AC IN
3
2
1
A
SIGNAL GND
SIGNAL GND
ON
4-Line
RS485(CAMERA) SET UP
MODE
ON
4-Line
MODE
VIDEO OUT 3
VIDEO OUT 4
VIDEO OUT 2
IN X-2
VIDEO OUT 1
ALARM IN
EXTENSION 3 IN
EXTENSION 2 IN
4
MODE
RS485 (CAMERA)
RS485 (CAMERA)
3
MODE
MODE
MODE
2
1
IN C-3
MODE
MODE
MODE
MODE
DATA
DATA
EXTENSION 1
TERM.
OFF
ON
OUT
IN
OUT X-3
1
2
3
4
TERM.ON
ON
MODE
TERM.OFF
MODE
DATA 4
HDR4/TMNL8
HDR2/TMNL4
DATA 3
HDR3/TMNL7
HDR1/TMNL3
DATA 2
TMNL6
TMNL2
DATA 1
TMNL5
TMNL1/PS DATA
Video Output Board 2
Video Output Board 1
OUT X-2
1
2
3
4
5
6
7
8
MONITOR OUT
9
10
11
12
13
14
15
16
IN X-1
16
15
14
13
12
11
10
9
CAMERA IN
8
7
6
5
4
3
2
1
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
NETWORK OUT X-1
ALARM OUT 2
ALARM OUT 1
SERIAL
VS OUT
VS IN
VS OUT
(THRU)
Video Output Board 1 Only
10/100 BASE-T
Mon1
Mon2
Mon3
Mon4
WJ-HD300A Series
WJ-SX650
WJ-SX650
1
1
8
2
IN
OUT
CASCADE
OUT
16
16
3
15
15
14
14
13
2
1
13
12
12
11
11
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
VIDEO
AUDIO IN
AUDIO OUT
MONITOR OUT CASCADE IN
MONITOR (VGA)
ALARM/CONTROL
SERIAL
ALARM
POWER
COPY 1
MODE
EXT STORAGE
10/100BASE-T
RS485(CAMERA)
DATA
AC IN
SIGNAL GND
1
4
2
3
C
1
2
B
1
2
3
AC IN
3
2
1
A
SIGNAL GND
SIGNAL GND
ON
4-Line
RS485(CAMERA) SET UP
MODE
ON
4-Line
MODE
VIDEO OUT 3
VIDEO OUT 4
VIDEO OUT 2
IN X-2
VIDEO OUT 1
ALARM IN
EXTENSION 3 IN
EXTENSION 2 IN
4
MODE
RS485 (CAMERA)
RS485 (CAMERA)
3
MODE
MODE
MODE
2
1
IN C-3
MODE
MODE
MODE
MODE
DATA
DATA
EXTENSION 1
TERM.
OFF
ON
OUT
IN
OUT X-3
1
2
3
4
TERM.ON
ON
MODE
TERM.OFF
MODE
DATA 4
HDR4/TMNL8
HDR2/TMNL4
DATA 3
HDR3/TMNL7
HDR1/TMNL3
DATA 2
TMNL6
TMNL2
DATA 1
TMNL5
TMNL1/PS DATA
Video Output Board 2
Video Output Board 1
OUT X-2
1
2
3
4
5
6
7
8
MONITOR OUT
9
10
11
12
13
14
15
16
IN X-1
16
15
14
13
12
11
10
9
CAMERA IN
8
7
6
5
4
3
2
1
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
NETWORK OUT X-1
ALARM OUT 2
ALARM OUT 1
SERIAL
VS OUT
VS IN
VS OUT
(THRU)
Video Output Board 1 Only
10/100 BASE-T
Mon1
Mon2
Mon3
Mon4
WJ-HD300A Series
1
1
8
2
IN
OUT
CASCADE
OUT
16
16
3
15
15
14
14
13
2
1
13
12
12
11
11
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
VIDEO
AUDIO IN
AUDIO OUT
MONITOR OUT CASCADE IN
MONITOR (VGA)
ALARM/CONTROL
SERIAL
ALARM
POWER
COPY 1
MODE
EXT STORAGE
10/100BASE-T
RS485(CAMERA)
DATA
AC IN
SIGNAL GND
1
4
2
PC with WJ-ASC960
Admin Console
System Controller
(Ethernet)
Switching HUB
Switching HUB
Switching
HUB
Switching HUB
Switching HUB
10BASE-T/100BASE-TX
SERIAL
2
1
OTHER
SYSTEM
DEVICE
SYSTEM
CONTROLLER
POWER
ON
AC IN
OFF
SIGNAL GND
WJ-MPU955A
(Equipped with WJ-ASC960)
WJ-MPU955A
(Equipped with WJ-ASC960)
PC with WJ-ASC960
Admin Console
System Controller
(Ethernet)
10BASE-T/100BASE-TX
SERIAL
2
1
OTHER
SYSTEM
DEVICE
SYSTEM
CONTROLLER
POWER
ON
AC IN
OFF
SIGNAL GND
172.18.0.1
172.16.192.2
172.18.0.1
192.168.200.200
192.168.200.200
172.16.192.1
Domain 1
Domain 2