Enter Global Operators in the WJ-ASC960 Admin Console (Global Database)
In the WJ-ASC960 Admin Console main screen, select
Operators
→
Records
on the
Components
menu. The
OPERATORS
screen will be activated. Then, enter the
operator(s)
information into the fields provided. For global
operator(s), you can select one of the four global class levels.
User ID
Password
Priority
Timeout
Name
Class
500
500
2
00:00:00
Global Operator 1
20: Global Level 0
100
123
10
00:00:00
Global Operator 2
20: Global Level 0
●
Enter Operator to Unit Partitioning in the WJ-ASC960 Admin Console
In the WJ-ASC960 Admin Console main screen, select
Operator
→
Records
on the
Components
menu. The
OPERATORS
screen will be activated. Then, select the
Unit
tab and check the partitioning you want to apply to a
global operator.
■
Additional GX Switch Node Setup
●
Setup Multicast IP Address for Encoder and Decoder Devices
The following steps are required to set up the multicast IP address for each system domain Encoder and Decoder.
Using the WJ-ASC960 Global Admin tool PC, launch Internet Explorer.
1) http://xxx.xxx.xxx.xxx
Enter the IP address (such as xxx.xxx.xxx.xxx) of the WJ-GXE900 or WJ-GXD900 in the address box of the Web
browser and press the ENTER key. The top page will be displayed.
2) Click the ‘SYSTEM’ button in the left column on the top page.
The authentication dialog window will be displayed. Enter a user name whose access level is 1 (ADMINISTRA-
TOR) and a password, and click the [OK] button. When authenticated, SYSTEM setup page will be displayed
3) Set the IP address into MULTICAST IP ADDRESS FOR SETUP by following table.
Unit ID
MULTICAST IP ADDRESS
1 (Default)
239.192.255.2 (Default)
2
239.192.255.3
3
239.192.255.4
4
239.192.255.5
5
239.192.255.6
62
239.192.255.63
63
239.192.255.64
64
239.192.255.65