48
***{ format 9 - Mmm/DD/'YY
}
TimeDateFormat=1
***{ Time-Hour Display format
}
***{ Format: TimeHourFormat=<format>
}
***{ format 0 - 12 Hour
}
***{ format 1 - 24 Hour
}
TimeHourFormat=0
[UNIT]
***{ The unit ID should be the same as the one defined in }
***{ the Global Admin database for this unit.
}
***{ For single-unit systems, use ID=1. (ID=0 is invalid)
}
ID=2
[LOG]
***{ This section is optional. It is not required unless
}
***{ System defaults are not acceptable. Delete the
}
***{ single asterisks below to make this section active.
}
***{ Log generation/save characteristics
}
***{ Format: <LogFileName>=<Minutes>,<Days>
}
***{ Minutes = Frequency to copy to HD (1 - 30 min)
}
***{ Note: Values outside this range = 1 min.
}
***{ Days = days to save on HD (5 - 30)
}
***{ Mode = 0 - off (default)
}
***{ 1 - on
}
UserLog=10,7,1
SwLog=10,7,0
AlarmLog=10,7,1
VideoLossLog=10,7,1
[RS232ALARM]
***{ This section is optional. It is not required unless
}
***{ System defaults are not acceptable. Delete the
}
***{ single asterisks below to make this section active.
}
***{ Enable/Disable Serial Alarms by port
}
***{ Note: Port 2 is dedicated to redundant communication
}
***{ if REDUNDANT:YES is selected by front panel
}
***{ switch.
}
***{ Format: AlarmPort=<port 1>,<port 2>
}
***{ port # = use "1" to indicate desired port (only one)
}
***{ port # = use "0" to indicate ports not desired
}
*AlarmPort=1,0
[ALARMTEXTDISPLAY]
***{ This section is optional. It is not required unless
}
***{ System defaults are not acceptable. Delete the
}
***{ single asterisks below to make this section active. }
***{ Alarm Text Display format
}
***{ Format: AlarmTextDisplay=<option>
}
***{ option 0 - Display Alarm Text only
}
***{ option 1 - Display both Alarm Text (20 chars)
}
***{ and Action Text (20 chars)
}
*AlarmTextDisplay=0
[SYSTEM]
***{ This section is optional. It is not required unless
}