background image

40

[OPERATORS]

ID

Password

Priority

Timeout

Name

Class

100

100

100

00:00:00

Normal

1: Normal

955

955

3

00:00:00

Super

2: Super

[DIGITAL RECORDER]

Admin Console sample database (02=multi_2.adm) work sheet for Unit2

[GX DEVICES]

Note:

Actual MAC address that is indicated on a product should be entered to EA field.

ID

I/F

IPA

EA

Encoder

Input

Ports

Decoder

Output

Ports

GXDIN

Input

Ports

1

0

192.168.3.10

00:00:00:00:00:00

1 - 4

1 - 4

Address

A

B

C

0

0

3

2

0

192.168.3.11

00:00:00:00:00:00

5 - 8

5 - 8

0

0

4

3

0

192.168.4.10

00:00:00:00:00:00

1 - 4

GXDOUT

Output

Ports

1 - 4

5 - 8

0

1

1

ID

Logical

Model

1

1

WJ-HD316A

Video

Switch

IPA

Cam

Port

Channels

GX

8

1

172.18.0.60

6.144

Digital

Bitrate

1

Unit

Address

1

2

2

3

3

4

4

5

5

6

6

7

7

Содержание WJ-ASC960

Страница 1: ... to connect or operate this product please read these instructions carefully and save this manual for future use No model number suffix is shown in this manual Upgrade Software Operating Instructions Model No WJ ASC960 ...

Страница 2: ...ine a Video Switch Node 21 GX Switch Node 21 GX Switch Node and its Domain 21 Enter Encoders and Decoders in the WJ ASC960 Admin Console 21 SX850 Switch Node 21 SX850 Switch Node and its Domain 22 Enter SX850 FRAMES in the WJ ASC960 Admin Console 22 SX650 Switch Node 22 SX650 Switch Node and its Domain 22 Enter SX650 SubNodes in the WJ ASC960 Admin Console 22 How to Identify a Video Switch Link 23...

Страница 3: ...end that you refer all tasks related to the system installation to qualified service personnel or system installers We recommend that you make a note of all your system settings and save them This will help you if you are required to change the system configuration or if an unexpected event or failure occurs We encourage you to obtain and read all the related documents referenced on page 4 and bec...

Страница 4: ...Windows and Internet Explorer are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries Other names of companies and products contained in these operating instructions may be trademarks or regis tered trademarks of their respective owners Software License Licence This product includes a software component that is licensed by GNU Lesser Gene...

Страница 5: ... devices matrix control devices matrix OSD devices and matrix digital I O devices SX650 switch node is formed with WJ SX650 matrix switch devices Video Link A video link is a connection that can pass video from one video switch node to another It can only transfer video in one specified direction In a WJ ASC960 based system a video link can be found in the following locations From SX850 matrix swi...

Страница 6: ...signs its domain number equal to its unit number An SX650 SX850 switch node is always inside a system domain while a GX switch node can be across more than one domain as shown in the following diagram System Domain Diagram WJ MPU955A CPU Unit 1 Central Processing Unit WJ MPU955A FAN ALARM HDD ACTIVE OPERATE Domain 1 Domain 2 PC with Admin Console System Controller WJ MPU955A Unit 1 WJ SX650 or WJ ...

Страница 7: ...E900 1 2 3 4 5 6 7 8 System Controller System Controller Central Processing Unit WJ MPU955A FAN ALARM HDD ACTIVE OPERATE WJ SX650 or WJ SX850 1 SX650 SX850 Switch Node OPERATE OPERATE LED WILL BLINK IF COOLING FAN MALFUNCTIONS Matrix Switcher WJ SX650 Central Processing Unit WJ MPU955A FAN ALARM HDD ACTIVE OPERATE Central Processing Unit WJ MPU955A FAN ALARM HDD ACTIVE OPERATE WJ SX650 or WJ SX850...

Страница 8: ...etwork and System Domains As stated on page 6 the WJ ASC960 system only has one GX switch node The digital video network is an IP based network which is created to transmit digital video streams within a system domain or cross multiple system domains It is part of the GX switch node which consists of all the GX encoder and encoder devices When designing a new system we recommend that you separate ...

Страница 9: ... two matrix video devices these two matrix video devices must be in different video switch nodes Encoder 1 Decoder 1 WJ GXE900 WJ GXD900 Encoder 2 Decoder 2 WJ GXE900 WJ GXD900 Matrix Switch 1 SX650 SX850 Node 1 GX Node Matrix Switch 2 SX650 SX850 Node 2 OPERATE STATUS MPEG2 Encoder WJ GXE900 1 2 3 4 5 6 7 8 OPERATE STATUS MPEG2 Encoder WJ GXE900 1 2 3 4 5 6 7 8 OPERATE 1 ACT 1000 100 LINK1 STATUS...

Страница 10: ...nsole V4 2 for both local database and global database setup WJ ASC960 Admin Console for Global Setup The administration tool WJ ASC960 V4 2 is database management software for multiple domain based system setup The software operates in the Microsoft Windows environment If users are familiar with previous versions of Panasonic system we used to have separated global administration tool software ju...

Страница 11: ...4 3 2 1 G 4 3 2 1 GGV G Switching HUB Switching HUB L3SW L2SW WJ GXE900 192 168 1 10 WJ HD300A Series 172 18 0 60 Digital Disk Recorder 1 POWER ON OFF SIGNAL AUDIO IN VIDEO OUT VIDEO IN 100BASE TX RS 485 TERM 1 GND 2 3 ON OFF 4 ALARM IN TRIGGER OUT RESET 4 3 2 1 G 4 3 2 1 GGV G WJ GXE900 192 168 1 11 WJ GXD900 192 168 3 11 WJ SX850 WJ MPU955A Equipped with WJ ASC960 DO NOTOPEN RISK OF ELECTRICSHOC...

Страница 12: ...0 Note The rotary dip switch valued should not be same as Encoder s one L3SW Setup Set the following IP Address to each port Port IP Address Connection 1 192 168 1 1 Encoder 1 2 2 192 168 3 1 Decoder 1 3 192 168 200 1 MPU955A Valid the IGMP V2 due to support Multicast messages Card Cage WJ SX850 Setup Refer to WJ SX850 Operational Manual to set following configuration Slot Board name model Rotary ...

Страница 13: ...GXD900 192 168 3 11 WJ SX850 SIGNAL GND POWER ON OFF 3 3 1 4 2 1 4 2 VIDEO OUT AUDIO OUT MIX RESET 1000BASE T 100BASE TX V G QUAD 192 168 1 1 192 168 3 1 192 168 200 1 192 168 3 11 172 18 0 1 192 168 200 200 10BASE T 100BASE TX SERIAL 2 1 OTHER SYSTEM DEVICE SYSTEM CONTROLLER POWER ON AC IN OFF SIGNAL GND 3 C 1 2 B 1 2 3 AC IN 3 2 1 A SIGNAL GND SIGNAL GND ON 4 Line RS485 CAMERA SET UP MODE ON 4 L...

Страница 14: ...p Same as System850 description L3SW Setup Same as System850 description WJ SX650 Setup Slot Board name Rotary Switch Mode Qty C Video Input Board 0 1 B A Video Output Board with Network Board Output Board 1 1 Digital Disk Recorder HD300A Series Setup Same as System850 description ...

Страница 15: ...4 Mon2 1 Mon2 2 Mon2 3 Mon2 4 Domain 1 1 1 8 2 IN OUT CASCADE OUT 16 16 3 15 15 14 14 13 2 1 13 12 12 11 11 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 VIDEO AUDIO IN AUDIO OUT MONITOR OUT CASCADE IN MONITOR VGA ALARM CONTROL SERIAL ALARM POWER COPY 1 MODE EXT STORAGE 10 100BASE T RS485 CAMERA DATA AC IN SIGNAL GND 1 4 2 WJ HD300A Series 172 18 0 60 Digital Disk Recorder 1 1 Digital Disk Recorder 2 ...

Страница 16: ...ult 2 1 239 192 255 3 2 2 239 192 255 3 Decoder WJ GXD900 Setup Refer to WJ GXD900 Operational Manual to set following configuration through the Web browser Decoder Operation Mode IP Address Subnet Mask Default Gateway DNS Rotary Switch 1 1 Main CPU mode 192 168 2 10 255 255 255 0 192 168 2 1 0 0 0 0 0 1 0 2 1 Main CPU mode 192 168 4 10 255 255 255 0 192 168 4 1 0 0 0 0 0 1 1 Decoder MULTICAST IP ...

Страница 17: ...1 1 CPU 2 Valid the IGMP V2 due to support Multicast messages Digital Disk Recorder HD300A Series Setup Digital Disk Recorder Line Speed HTTP Port Number DHCP IP Address 1 1 AUTO 00080 OFF 172 018 000 060 2 1 AUTO 00080 OFF 172 018 000 060 Subnet Mask Gateway Unit Address System Unit Address Controller 255 255 000 000 000 000 000 000 001 001 255 255 000 000 000 000 000 000 001 001 ...

Страница 18: ...CASCADE OUT 16 16 3 15 15 14 14 13 2 1 13 12 12 11 11 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 VIDEO AUDIO IN AUDIO OUT MONITOR OUT CASCADE IN MONITOR VGA ALARM CONTROL SERIAL ALARM POWER COPY 1 MODE EXT STORAGE 10 100BASE T RS485 CAMERA DATA AC IN SIGNAL GND 1 4 2 3 C 1 2 B 1 2 3 AC IN 3 2 1 A SIGNAL GND SIGNAL GND ON 4 Line RS485 CAMERA SET UP MODE ON 4 Line MODE VIDEO OUT 3 VIDEO OUT 4 VIDEO O...

Страница 19: ...d name Rotary Switch Mode Qty C Video Input Board 0 1 B A Video Output Board with Network Board Output Board 1 1 Digital Disk Recorder HD300A Series Setup Same as Single System Domain with Both GX and SX850 Switch Node on page 12 ...

Страница 20: ...er the Unit s information into the fields provided In the following table we used the example on page 15 to show what information you would need to enter Unit ID Main IPA A Backup IPA B Unit Name Size 1 172 16 192 1 Domain 1 Enhanced 2 172 16 192 2 Domain 2 Enhanced Enter Unit ID in the System Configuration File In each WJ MPU955A CPU there is a system configuration file named SYS INI You can view...

Страница 21: ...er Encoders and Decoders in the WJ ASC960 Admin Console After deciding the domain ID for each encoder and decoder the next step is to enter the encoder and decoder device information in the WJ ASC960 Admin Console for the domain In the WJ ASC960 Admin Console GX DEVICES screen we need to configure the devices here Since these devices are part of the digital node select GX from the Switch Nodes com...

Страница 22: ...more WJ SX650 matrix switcher with WJ PB65E01 network board SX650 switch node can only be located within a system domain and cannot cross over multiple domains Currently the system only supports up to one SX650 switch node in a single system domain and node ID is always set to its domain ID by the system software SX650 Switch Node and its Domain In case of a single domain system all the WJ SX650 m...

Страница 23: ...be acti vated Then enter the video link s information into the fields provided In the following table we used the example on page 11 to show what information you would need to enter In the above video link table users are able to enable or disable a video link When disabled the system will not use that link in its video routing operation Also in the above video link table the destination unit ID a...

Страница 24: ...y to a global operator Additional GX Switch Node Setup Setup Multicast IP Address for Encoder and Decoder Devices The following steps are required to set up the multicast IP address for each system domain Encoder and Decoder Using the WJ ASC960 Global Admin tool PC launch Internet Explorer 1 http xxx xxx xxx xxx Enter the IP address such as xxx xxx xxx xxx of the WJ GXE900 or WJ GXD900 in the addr...

Страница 25: ...e a standalone WJ MPU955A system to a distributed WJ ASC960 system please refer to MPEG2 Encoder WJ GXE900 MPEG2 Decoder WJ GXD900 Operating Instructions With this upgrade you can create a multiple domain system that forms a large scale system ...

Страница 26: ...t only allows the highest priority operator to perform this func tion The next highest priority operator gains control when the highest priority operator releases the resource Here is a sample operation to switch video from local camera number 1 in domain 1 to another camera number 1 in domain 2 on a local monitor number 1 1 Login to System Controller Enter 500 for ID and enter 500 for password Gl...

Страница 27: ...n Global Recorder Selection Operators must seize a digital disk recorder in order to perform recorder operations After Global Video Switch and Video Routing refer to page 26 you can seize a recorder 200001 which means a recorder in domain 2 with a recorder ID of 1 Recorder Basic Operation The system provides operators with the following video recorder functions Recording Playback pause and stop Fa...

Страница 28: ...tor 1 Enter 1 and press MONITOR key Tour Sequence Operation Tour sequence operations include start stop pause run next step and previous step Here is the sample to start a tour sequence Run global tour sequence 1 Domain 2 s tour sequence 1 Enter 20010001 and press TOURSEQ key Notes Format Domain id 2 Area number 1 Tour number 1 E g 20010001 Only Global Operator can access foreign domain resources ...

Страница 29: ...that the alarm originates from that domain Setup an Exported Alarm in WJ ASC960 Admin Console After creating an alarm to be exported to a destination domain an administrator must enter the alarm information into the destination domain alarm database using its WJ ASC960 Admin Console In the WJ ASC960 Admin Console main menu select Records from the Alarm command on the Components menu For alarm sour...

Страница 30: ... operator subjects to the cam era unit partitioning Check whether you enter a correct unit id for the global camera Check whether global database has been updated for this operator Users typed correct password Troubleshooting Before contacting technical support please check the following symptoms and their possible causes and solutions If the solutions suggested do not solve the problem or if the ...

Страница 31: ...31 Standard Accessories CD ROM 1 Installation Guide 1 Certification Label 1 Note The files specified below are included on the CD ROM Operating Instructions pdf Administration Console ...

Страница 32: ... 1 256 1 32 LCPU Address SW12 SW10 SW9 0 2 0 CAMERAS OSD ID Control Compensation Bitrate Model 1 SX850 1 Short Switch Port MXCONT MXOSD MXOSD 2 SX850 2 Short MXOSD 3 SX850 3 Short MXOSD 4 5 Logical 1 2 3 4 SX850 4 Short Title C 1 C 2 C 3 C 4 C 5 C 6 C 7 C 8 C 9 C 10 C 11 C 12 C 13 C 14 C 15 C 16 MXOSD 5 SX850 5 Short MXOSD 6 6 SX850 6 Short MXOSD 7 7 SX850 7 Short MXOSD 8 8 SX850 8 Short MXOSD 9 9...

Страница 33: ...ocal Switch Port 1 0 1 SX850 1 2 0 2 SX850 2 3 0 3 SX850 3 4 0 4 SX850 4 OPERATORS User ID Password Priority Timeout Name Class 100 100 100 00 00 00 Normal 1 Normal 955 955 3 00 00 00 Super 2 Super DIGITAL RECORDER ID Logical Model Video Switch IPA Cam Port Channels 1 1 WJ HD316A SX850 13 1 172 18 0 60 Digital Bitrate 1 Unit Address 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 1...

Страница 34: ...72 18 0 1 Domain 1 Enhanced LINK OPERATORS User ID Password Priority Timeout Name Class 500 500 2 00 00 00 Global Operator 20 Global Level 0 Link ID 1 Enable 1 Video Source Unit ID Switch Video Destination Navigation Cost Port Unit ID GX 1 1 SX850 9 1 2 1 GX 2 1 SX850 10 1 3 4 1 GX 4 1 SX850 12 1 1 GX 3 1 SX850 11 1 Switch Port ...

Страница 35: ...ce_num All others use num_functions interface_num All 0 s used for digital only systems MXSWFunction 1 1 1 MXCONTFunction 1 1 MXOSDFunction 1 1 MXDIOFunction 1 1 MXRMSFunction 0 0 PROCS Process Interface Assignments Format Process Name interface_num Set these three to the interface_num of the Ethernet keyboards Keybp 1 Mxconts 1 Mxpfw 1 Set Swcpu to the interface_num of the MainCPU Swcpu 1 Set Uni...

Страница 36: ... UNIT The unit ID should be the same as the one defined in the Global Admin database for this unit For single unit systems use ID 1 ID 0 is invalid ID 1 LOG This section is optional It is not required unless System defaults are not acceptable Delete the single asterisks below to make this section active Log generation save characteristics Format LogFileName Minutes Days Minutes Frequency to copy t...

Страница 37: ...Cameras 1024 Monitors 256 ROUTING This section is optional to the system It is only required for external gateway Only one default gateway entry is allowed Format default gateway IPA default 192 168 200 1 Network entries must be grouped together although any number of entries is allowed Format network destination gateway netmask network 64 0 0 0 192 168 200 44 255 0 0 0 network 88 0 0 0 192 168 20...

Страница 38: ...erIPA IPA of SNTP server for Unicast mode only optional for modes 0 2 3 ExternalFrequency time frequency of sync secs default is 18000 sec 5 hrs TZOffset hour time zone offset from GMT 12 in integer values DaylightSaving on off applies for the local time zone on off 0 off 1 on ClientMode 1 ServerMode 1 InternalFrequency 600 NTPServerIPA 192 168 200 XXX ExternalFrequency 18000 TZOffset 5 DaylightSa...

Страница 39: ...C 7 6 144 5 GX 5 Short 6 144 6 6 GX 6 Short 6 144 7 7 GX 7 Control GX 1 Switch Port GX 2 GX 3 GX 4 GX 5 GX 6 GX 7 Short 6 144 CAMERAS CONTROLLERS ID Area Priority Boot File Model IPA EA Port 1 0 3 WV CU950 172 18 0 200 00 80 45 AB CD EF Note Actual MAC address that is indicated on a product should be entered to EA field MONITORS ID Area Local Switch Port 1 0 1 GX 1 2 0 2 GX 2 3 0 3 GX 3 4 0 4 GX 4...

Страница 40: ...cated on a product should be entered to EA field ID I F IPA EA Encoder Input Ports Decoder Output Ports GXDIN Input Ports 1 0 192 168 3 10 00 00 00 00 00 00 1 4 1 4 Address A B C 0 0 3 2 0 192 168 3 11 00 00 00 00 00 00 5 8 5 8 0 0 4 3 0 192 168 4 10 00 00 00 00 00 00 1 4 GXDOUT Output Ports 1 4 5 8 0 1 1 ID Logical Model 1 1 WJ HD316A Video Switch IPA Cam Port Channels GX 8 1 172 18 0 60 6 144 Di...

Страница 41: ...Password Priority Timeout Name Class 100 100 100 00 00 00 Normal 1 Normal 955 955 3 00 00 00 Super 2 Super CAMERAS ID Control Video Compensation Bitrate Model OSD 1 GX GX 1 2 3 4 5 6 7 Short Switch Port Switch Port WV CS954 WV CS954 WV CS954 WV CS954 WV CS954 WV CS954 WV CS954 6 144 MXCONT MXOSD 2 GX GX Short 6 144 3 GX GX Short 6 144 4 5 Logical 1 2 3 4 GX GX Short Title C 1 C 2 C 3 C 4 C 5 C 6 C...

Страница 42: ...omain 1 Enhanced 2 172 16 192 2 Domain 2 Enhanced System User User ID Password Priority Timeout Name Class 500 500 2 00 00 00 Global Operator 20 Global Level 0 501 501 2 00 00 00 Global Operator 20 Global Level 0 ID Logical Model 1 1 WJ HD316A Video Switch IPA Cam Port Channels GX 8 1 172 18 0 60 6 144 Digital Bitrate 1 Unit Address 1 2 2 3 3 4 4 5 5 6 6 7 7 ...

Страница 43: ...at num_rows num_cols interface_num All others use num_functions interface_num All 0 s used for digital only systems MXSWFunction 0 0 0 MXCONTFunction 0 0 MXOSDFunction 0 0 MXDIOFunction 0 0 MXRMSFunction 0 0 PROCS Process Interface Assignments Format Process Name interface_num Set these three to the interface_num of the Ethernet keyboards Keybp 1 Mxconts 1 Mxpfw 1 Set Swcpu to the interface_num of...

Страница 44: ...HourFormat format format 0 12 Hour format 1 24 Hour TimeHourFormat 0 UNIT The unit ID should be the same as the one defined in the Global Admin database for this unit For single unit systems use ID 1 ID 0 is invalid ID 1 LOG This section is optional It is not required unless System defaults are not acceptable Delete the single asterisks below to make this section active Log generation save charact...

Страница 45: ... unit Monitors num of monitors on this unit Keyboards 64 Cameras 1024 Monitors 256 ROUTING This section is optional to the system It is only required for external gateway Only one default gateway entry is allowed Format default gateway IPA default 192 168 200 1 Network entries must be grouped together although any number of entries is allowed Format network destination gateway netmask network 64 0...

Страница 46: ...quency 600 NTPServerIPA 192 168 200 XXX ExternalFrequency 18000 TZOffset 5 DaylightSaving 1 ERRORP ErrorLevel 3 sys ini configuration for Unit2 02A sys ini INTERFACES Number of interfaces in the system Numinterfaces 3 Interface Definitions Interface Number IPA SUBNET MASK BOOT SERVER IPA Note The InterfaceX IPAs must match the MainX CPU hardware settings in order for the System to operate correctl...

Страница 47: ...interface_num for all system CPUs SSntp 2 Set SNMPAgent to the same interface_num for all system CPUs SNMPAgent 2 OSD Initial OSD display position Alarm text is placed on the General Status line Format DisplayItemPosition x position y position TimeDatePosition 1 1 CamTitlePosition 1 16 MonStatusPosition 1 15 GenStatusPosition 1 14 Time Date Camera Title and Camera ID Controls Code 2 takes effect o...

Страница 48: ...0 7 0 AlarmLog 10 7 1 VideoLossLog 10 7 1 RS232ALARM This section is optional It is not required unless System defaults are not acceptable Delete the single asterisks below to make this section active Enable Disable Serial Alarms by port Note Port 2 is dedicated to redundant communication if REDUNDANT YES is selected by front panel switch Format AlarmPort port 1 port 2 port use 1 to indicate desir...

Страница 49: ...lthough any number of entries is allowed Format host destination gateway host 33 44 55 66 192 168 200 66 host 11 22 33 44 192 168 200 44 SNTP This section is optional It is not required unless System defaults are not acceptable Delete the single asterisks below to make this section active This section lists user defined client SNTP values sync rates and an external server address Format VALUES INT...

Страница 50: ...50 1 on ClientMode 1 ServerMode 1 InternalFrequency 600 NTPServerIPA 192 168 200 XXX ExternalFrequency 18000 TZOffset 5 DaylightSaving 1 ERRORP ErrorLevel 3 ...

Страница 51: ...SD 1 Logical 1 SX650 1 SX650 1 Short WJ CS954 Title C 1 2 2 SX650 2 SX650 2 Short WJ CS954 C 2 3 3 SX650 3 SX650 3 Short WJ CS954 C 3 4 4 SX650 4 SX650 4 Short WJ CS954 C 4 5 5 SX650 5 SX650 5 Short WJ CS954 C 5 6 6 SX650 6 SX650 6 Short WJ CS954 C 6 7 7 SX650 7 SX650 7 Short WJ CS954 C 7 8 8 SX650 8 SX650 8 Short WJ CS954 C 8 9 9 GX 9 GX 9 Short 6 144 WJ CS954 C 9 10 10 GX 10 GX 10 Short 6 144 WJ...

Страница 52: ...a Local Switch Port 1 0 1 SX650 1 2 0 2 SX650 2 3 0 3 SX650 3 4 0 4 SX650 4 OPERATORS ID Password Priority Timeout Name Class 100 100 100 00 00 00 Normal 1 Normal 955 955 3 00 00 00 Super 2 Super DIGITAL RECORDER ID Logical Model 1 1 WJ HD316A Video Switch IPA Cam Port Channels SX650 13 1 172 18 0 60 Digital Bitrate 1 Unit Address 1 2 2 3 3 4 4 5 5 6 6 7 7 8 9 10 11 12 13 14 15 16 8 9 10 11 12 13 ...

Страница 53: ...me Size 1 172 18 0 1 Unit 1 Enhanced LINK OPERATORS User ID Password Priority Timeout Name Class 500 500 2 00 00 00 Global Operator 20 Global Level 0 1 1 GX 1 1 SX650 9 1 2 1 GX 2 1 SX650 10 1 3 1 GX 3 1 SX650 11 1 4 1 GX 4 1 SX650 12 1 Enable Video Source Video Destination Navigation Cost Unit ID Unit ID Switch Switch Port Port ...

Страница 54: ..._cols interface_num All others use num_functions interface_num All 0 s used for digital only systems MXSWFunction 1 1 1 MXCONTFunction 1 1 MXOSDFunction 1 1 MXDIOFunction 1 1 MXRMSFunction 0 0 PROCS Process Interface Assignments Format Process Name interface_num Set these three to the interface_num of the Ethernet keyboards Keybp 1 Mxconts 1 Mxpfw 1 Set Kexs to the interface_num of the RS485 Expan...

Страница 55: ...m YY format 8 YY MM DD format 9 Mmm DD YY TimeDateFormat 1 Time Hour Display format Format TimeHourFormat format format 0 12 Hour format 1 24 Hour TimeHourFormat 0 UNIT The unit ID should be the same as the one defined in the Global Admin database for this unit For single unit systems use ID 1 ID 0 is invalid ID 1 RMS This section is optional It is not required unless System defaults are not accep...

Страница 56: ... optional It is not required unless System defaults are not acceptable Delete the single asterisks below to make this section active Alarm Text Display format Format AlarmTextDisplay option option 0 Display Alarm Text only option 1 Display both Alarm Text 20 chars and Action Text 18 chars AlarmTextDisplay 0 SYSTEM This section is optional It is not required unless System defaults are not acceptabl...

Страница 57: ...external server address Format VALUES INTERNAL TO THIS UNIT ClientMode mode act as an SNTP client modes 0 Internal default 1 Unicast 2 Anycast 3 Broadcast ServerMode mode to expose its timestamp to other units modes 0 Off 1 On default InternalFrequency time frequency of sync secs default is 600 sec 10 min VALUES FOR EXTERNAL CONNECTION NTPServerIPA IPA of SNTP server for Unicast mode only optional...

Страница 58: ...1 2 0 2 SX650 2 3 0 3 SX650 3 4 0 4 SX650 4 OPERATORS ID Password Priority Timeout Name Class 100 100 100 00 00 00 Normal 1 Normal 955 955 3 00 00 00 Super 2 Super ID 1 0 192 168 200 100 1 256 1 32 1 256 1 32 5 6 7 8 OFF OFF OFF OFF I F IP Address BRIDGE CONTROL OSD SWITCH ALARM Address MODE ID Video Compensation Bitrate Model OSD Title 1 Logical 1 SX650 1 SX650 1 Short WJ CS954 C 1 2 2 SX650 2 SX...

Страница 59: ...Short WJ CS954 C 1 2 2 SX650 2 SX650 2 Short WJ CS954 C 2 3 3 SX650 3 SX650 3 Short WJ CS954 C 3 4 4 SX650 4 SX650 4 Short WJ CS954 C 4 5 5 SX650 5 SX650 5 Short WJ CS954 C 5 6 6 SX650 6 SX650 6 Short WJ CS954 C 6 7 7 SX650 7 SX650 7 Short WJ CS954 C 7 8 8 SX650 8 SX650 8 Short WJ CS954 C 8 Control Switch Port Switch Port DIGITAL RECORDER CAMERAS ID Logical Model 1 1 WJ HD316A Video Switch IPA Cam...

Страница 60: ...A field MONITORS ID Area Local Switch Port 1 0 1 SX650 1 2 0 2 SX650 2 3 0 3 SX650 3 4 0 4 SX650 4 OPERATORS ID Password Priority Timeout Name Class 100 100 100 00 00 00 Normal 1 Normal 955 955 3 00 00 00 Super 2 Super DIGITAL RECORDER ID Logical Model 1 1 WJ HD316A Video Switch IPA Cam Port Channels SX650 9 1 172 18 0 60 Digital Bitrate 1 Unit Address 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 ...

Страница 61: ...imeout Name Class 500 500 2 00 00 00 Global Operator 20 Global Level 0 501 501 2 00 00 00 Global Operator 20 Global Level 0 Link ID 1 1 SX650 13 2 SX650 13 1 2 1 SX650 14 2 SX650 14 1 3 1 SX650 15 2 SX650 15 1 4 5 1 2 SX650 SX650 16 13 2 1 SX650 SX650 16 13 1 1 6 2 SX650 14 1 SX650 14 1 7 2 SX650 15 1 SX650 15 1 8 2 SX650 16 1 SX650 16 1 Enable Video Source Video Destination Navigation Cost Unit I...

Страница 62: ...s num_cols interface_num All others use num_functions interface_num All 0 s used for digital only systems MXSWFunction 0 0 0 MXCONTFunction 0 0 MXOSDFunction 0 0 MXDIOFunction 0 0 MXRMSFunction 0 0 PROCS Process Interface Assignments Format Process Name interface_num Set these three to the interface_num of the Ethernet keyboards Keybp 1 Mxconts 1 Mxpfw 1 Set Kexs to the interface_num of the RS485 ...

Страница 63: ... DD Mmm YY format 8 YY MM DD format 9 Mmm DD YY TimeDateFormat 1 Time Hour Display format Format TimeHourFormat format format 0 12 Hour format 1 24 Hour TimeHourFormat 0 UNIT The unit ID should be the same as the one defined in the Global Admin database for this unit For single unit systems use ID 1 ID 0 is invalid ID 1 LOG This section is optional It is not required unless System defaults are not...

Страница 64: ...ired unless System defaults are not acceptable Delete the single asterisks below to make this section active Format Keyboards num of controllers on this unit Cameras num of cameras on this unit Monitors num of monitors on this unit Keyboards 64 Cameras 1024 Monitors 256 ROUTING This section is optional to the system It is only required for external gateway Only one default gateway entry is allowed...

Страница 65: ... of sync secs default is 18000 sec 5 hrs TZOffset hour time zone offset from GMT 12 in integer values DaylightSaving on off applies for the local time zone on off 0 off 1 on ClientMode 1 ServerMode 1 InternalFrequency 600 NTPServerIPA 192 168 200 XXX ExternalFrequency 18000 TZOffset 5 DaylightSaving 1 ERRORP ErrorLevel 3 sys ini configuration for Unit2 02 A sys ini INTERFACES Number of interfaces ...

Страница 66: ...nsion Unit Kexs 1 Set Swcpu to the interface_num of the MainCPU Swcpu 1 Set UnitManager to the same interface_num for all system CPUs UnitManager 2 Set CSntp to the interface_num for EXTERNAL SNTP operation CSntp 2 Set SSntp to the same interface_num for all system CPUs SSntp 2 Set SNMPAgent to the same interface_num for all system CPUs SNMPAgent 2 OSD Initial OSD display position Alarm text is pl...

Страница 67: ...re not acceptable Delete the single asterisks below to make this section active Log generation save characteristics Format LogFileName Minutes Days Minutes Frequency to copy to HD 1 30 min Note Values outside this range 1 min Days days to save on HD 5 30 Mode 0 off default 1 on UserLog 10 7 1 SwLog 10 7 0 AlarmLog 10 7 1 VideoLossLog 10 7 1 RS232ALARM This section is optional It is not required un...

Страница 68: ...try is allowed Format default gateway IPA default 192 168 201 1 Network entries must be grouped together although any number of entries is allowed Format network destination gateway netmask network 64 0 0 0 192 168 200 44 255 0 0 0 network 88 0 0 0 192 168 200 88 255 0 0 0 network 33 5 0 0 192 168 200 66 255 0 0 0 network 64 0 0 0 192 168 200 55 255 0 0 0 Host entries must be grouped together alth...

Страница 69: ...tional for modes 0 2 3 ExternalFrequency time frequency of sync secs default is 18000 sec 5 hrs TZOffset hour time zone offset from GMT 12 in integer values DaylightSaving on off applies for the local time zone on off 0 off 1 on ClientMode 1 ServerMode 1 InternalFrequency 600 NTPServerIPA 192 168 200 XXX ExternalFrequency 18000 TZOffset 5 DaylightSaving 1 ERRORP ErrorLevel 3 ...

Страница 70: ...c equipment please contact your dealer or supplier for further information Information on Disposal in other Countries outside the European Union This symbol is only valid in the European Union If you wish to discard this product please contact your local authorities or dealer and ask for the correct method of disposal For U S Canadian and Puerto Rican fields Panasonic System Solutions Company Unit...

Отзывы: