12
●
Encoder WJ-GXE900 Setup
• Refer to WJ-GXE900 Operational Manual to set following configuration through the Web browser.
Encoder #
Operation Mode
IP Address
Subnet Mask
Default Gateway
DNS
Rotary Switch
1
Main CPU mode
192.168.1.10
255.255.255.0
192.168.1.1
0.0.0.0
0-0-1
2
Main CPU mode
192.168.1.11
255.255.255.0
192.168.1.1
0.0.0.0
0-0-2
●
Decoder WJ-GXD900 Setup
• Refer to WJ-GXD900 Operational Manual to set following configuration through the Web browser.
Decoder #
Operation Mode
IP Address
Subnet Mask
Default Gateway
DNS
Rotary Switch
1
Main CPU mode
192.168.3.11
255.255.255.0
192.168.3.1
0.0.0.0
0-1-0
Note:
The rotary dip-switch valued should not be same as Encoder’s one.
●
L3SW Setup
• Set the following IP Address to each port.
Port #
IP Address
Connection
1
192.168.1.1
Encoder #1,2
2
192.168.3.1
Decoder #1
3
192.168.200.1
MPU955A
• Valid the IGMP V2 due to support Multicast messages.
●
Card Cage WJ-SX850 Setup
• Refer to WJ-SX850 Operational Manual to set following configuration.
Slot #
Board name/model #
Rotary Switch
Qty
–
LCPU
0-2-0
Included
1
WJ-PB85X08
0-0
1
2
WJ-PB85Y08
–
1
15
WJ-PB85C16
0-0
1
16
WJ-PB85T08
0-0
1
17
WJ-PB85M16
0-0
1
–
WJ-CA85L05(Multiple Video cable)
–
3
●
Digital Disk Recorder HD300A Series Setup
Digital Disk Recorder#
Line Speed
HTTP Port Number
DHCP
IP Address
1
AUTO
00080
OFF
172.018.000.060
Subnet Mask
Gateway
Unit Address (System)
Unit Address (Controller)
255.255.000.000
000.000.000.000
001
001