![Panasonic WJ-ASC960 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/panasonic/wj-asc960/wj-asc960_operating-instructions-manual_278220029.webp)
29
■
Alarm Export to other Domains
●
Alarm Export Function
This function allows administrators to assign an alarm export to another system domain.
●
Assign Alarm Export in WJ-ASC960 Admin Console
In the WJ-ASC960 Admin main screen, select
Components
→
Alarms
→
Records
→
Export
tab. From there, you can
add, delete, and edit an alarm to be exported to multiple system domains (units). The alarm ID has the following for-
mat:
Domain (Unit) id (2) + Alarm id (1).
E.g. 20001
In the above format, the domain ID has up to 2 digits and its range is from 1 … 64. The domain ID here is also called
alarm source domain, which means that the alarm originates from that domain.
●
Setup an Exported Alarm in WJ-ASC960 Admin Console
After creating an alarm to be exported to a destination domain, an administrator must enter the alarm information
into the destination domain alarm database using its WJ-ASC960 Admin Console.
In the WJ-ASC960 Admin Console main menu, select
Records
from the
Alarm
command on the
Components
menu. For alarm source, select the source type Global Alarm and ID to 20001 (in the above case).
You should also go to the alarm target screen and action screen to complete your normal alarm setup.
■
System Wide Log View
The system supports the following system logs:
• Operator log
• Alarm log
In the WJ-ASC960 Admin Console main screen select the
Tools, Logs, and System
links to view system wide user
logs and alarm logs.