![Panasonic WJ-ASC960 Скачать руководство пользователя страница 66](http://html.mh-extra.com/html/panasonic/wj-asc960/wj-asc960_operating-instructions-manual_278220066.webp)
66
***{ MainB CPU }
*Interface0=192.168.200.201,255,255,255,0,192.168.200.201
*Interface1=172.18.0.2,255.255.0.0,172.18.0.2
*Interface2=172.16.192.2,255.255.0.0,172.16.192.2
[FRAMES]
***{ MX Frame definition from Admin file
}
***{ MXSW has format <num_rows>,<num_cols>,<interface_num> }
***{ All others use <num_functions>,<interface_num>
}
***{ All 0's used for digital-only systems.
}
MXSWFunction=0,0,0
MXCONTFunction=0,0
MXOSDFunction=0,0
MXDIOFunction=0,0
MXRMSFunction=0,0
[PROCS]
***{ Process Interface Assignments
}
***{ Format: <Process Name>=<interface_num>
}
***{ Set these three to the interface_num of the Ethernet keyboards:
}
Keybp=1
Mxconts=1
Mxpfw=1
***{ Set Kexs to the interface_num of the RS485 Expansion Unit:
}
Kexs=1
***{ Set Swcpu to the interface_num of the MainCPU:
}
Swcpu=1
***{ Set UnitManager to the same interface_num for all system CPUs:
}
UnitManager=2
***{ Set CSntp to the interface_num for EXTERNAL SNTP operation:
}
CSntp=2
***{ Set SSntp to the same interface_num for all system CPUs:
}
SSntp=2
***{ Set SNMPAgent to the same interface_num for all system CPUs:
}
SNMPAgent=2
[OSD]
***{ Initial OSD display position
}
***{ Alarm text is placed on the General Status line.
}
***{ Format: <DisplayItemPosition>=<x-position>,<y-position> }
TimeDatePosition=1,1
CamTitlePosition=1,16
MonStatusPosition=1,15
GenStatusPosition=1,14
***{ Time-Date, Camera Title and Camera ID Controls }
***{ Code 2 takes effect only if source is MXOSD
}
***{ Format: <Control Name>=<control code>
}
***{ control code 0 - OFF
}
***{ control code 1 - ON
}
***{ control code 2 - By Operator
}
TimeDateControl=2
CamTitleControl=2
CamIDControl=2
***{ Time and Date display format
}