70 °C
40 °C ~ 75 °C
-
1 day ~ 99 days
The current day and time need to be set in cases below:
•
- A long time has elapsed since the power was turned on the
9
Booster Heater
To activate or deactivate the water tank’s booster heater.
Note: If NO is selected, menu 10 is skipped.
10
Booster Heater Delay Timer
To delay time for the booster heater to activate while the system is
heating up the water tank.
1 hour
20 minutes ~
1 hour 35 minutes
• Do not use the system during sterilisation in order to prevent scalding with hot water, or overheating of shower.
• Ask an authorised dealer to determine the level of sterilisation function field settings according to the local laws and
regulations.
11
Sterilisation
To sterilise the water tank, if required.
Note: If NO is selected, menus 12 to 14 are skipped.
12
Sterilisation Day & Time
To set timer for sterilisation.
(Only once a week. Operates even under a standby condition)
Monday
12:00
Monday ~ Sunday
0:00 ~ 23:50
13
Sterilisation Temperature
To set the temperature of sterilisation.
14
Continuation of Sterilisation
To maintain heating temperature in order to complete the
sterilisation.
10 minutes
5 minutes ~
1 hour
15
Base Pan Heater
To select whether or not to connect to the optional base pan
heater.
Note: If NO is selected, menu 16 is skipped.
16
Base Pan Heater type
Type A - The base pan heater activates only during deice
operation.
Type B - The base pan heater activates when outdoor ambient
temperature is 5 °C or lower.
17
Dry Concrete
During construction to dry the concrete under a preset
temperature.
Do not use this menu for any other purposes and in period other
than during construction (Refer to information page).
User
Remote control preparation
1
Press
.
2
Press
or
to set the current day.
3
Press
to confirm.
4
2
3
■
Note:
- When the power is turned on for the first time.
last time.
• The current time that has been set will be the standard time for
all the timer operations.
Caution Indicator (Tank Temperature above 60 °C)
Dealer
Operation/settings to be done only by the authorised dealer/specialist.
User
Operation/settings to be done by the authorised dealer/specialist or user.
Repeat steps
and
to set the current time.
Содержание WH-MHF09G3E8
Страница 32: ...32 10 1 2 Solar Printed Circuit Board Optional ...
Страница 33: ...33 10 2 Refrigerant System 10 2 1 Main Printed Circuit Board ...
Страница 34: ...34 10 2 1 1 Noise Filter Printed Circuit Board ...
Страница 47: ...47 Heat Mode Operation Time Chart ...
Страница 49: ...49 ...
Страница 50: ...50 ...
Страница 56: ...56 ...
Страница 57: ...57 ...
Страница 58: ...58 ...
Страница 127: ...127 17 3 To Remove The Cabinet Rear Plate 17 4 To Remove Pressure Gauge 17 5 To Remove RCCB ...
Страница 134: ...134 6 25 68 30 5 2 9 7 8 4 27 1 3 21 23 26 62 8 75 24 71 49 48 20 13 12 10 11 4 15 77 71 13 15 78 14 ...
Страница 138: ...138 19 2 Water System 44 46 17 16 4 34 42 18 43 3 33 9 1 45 45 47 2 35 48 36 19 ...