6
Item
Unit
Mono Bloc Unit
Power factor means total figure of compressor and outdoor fan motor.
Power Cord
Number of core
-
Length
m (ft)
-
Thermostat
Electronic Control
Protection Device
Electronic Control
Item
Unit
Water System
Performance Test Condition
EN14511
Operation Range
Outdoor Ambient
°C
-20 ~ 35
Water Outlet
°C
25 ~ 65
Internal Pressure Differential
kPa
26.5
Water Pipe Diameter
Inlet
mm (inch)
30 (1-3/16)
Outlet
mm (inch)
30 (1-3/16)
Water Drain Hose Inner Diameter
mm (inch)
15.00 (19/32)
Pump
Motor Type
DC Motor
No. of Speed
7 (Software Selection)
Input Power
W
58
Hot Water Coil
Type
Brazed Plate
No. of Plates
80
Size (W x H x L)
mm
130 × 93 × 325
Water Flow Rate
l/min (m
3
/h)
25.8 (1.5)
Pressure Relief Valve Water Circuit
kPa
Open: 300, Close: 265 and below
Flow Switch
Magnetic Lead Switch
Protection Device
A
Residual Current Circuit Breaker (25)
Expansion Vessel
Volume
I
10
MWP
bar
3
Capacity of Integrated Electric Heater
kW
3.00
Note:
Heating capacities are based on outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb
(42.8°F Wet Bulb) with controlled water inlet temperature of 30°C and water outlet temperature of 35°C.
Specification are subjected to change without prior notice for further improvement.
Содержание WH-MHF09G3E8
Страница 32: ...32 10 1 2 Solar Printed Circuit Board Optional ...
Страница 33: ...33 10 2 Refrigerant System 10 2 1 Main Printed Circuit Board ...
Страница 34: ...34 10 2 1 1 Noise Filter Printed Circuit Board ...
Страница 47: ...47 Heat Mode Operation Time Chart ...
Страница 49: ...49 ...
Страница 50: ...50 ...
Страница 56: ...56 ...
Страница 57: ...57 ...
Страница 58: ...58 ...
Страница 127: ...127 17 3 To Remove The Cabinet Rear Plate 17 4 To Remove Pressure Gauge 17 5 To Remove RCCB ...
Страница 134: ...134 6 25 68 30 5 2 9 7 8 4 27 1 3 21 23 26 62 8 75 24 71 49 48 20 13 12 10 11 4 15 77 71 13 15 78 14 ...
Страница 138: ...138 19 2 Water System 44 46 17 16 4 34 42 18 43 3 33 9 1 45 45 47 2 35 48 36 19 ...