42
11.4.2 Connecting Requirement
For model WH-MHF09G3E8:
The equipment’s power supply 1 complies with IEC/EN 61000-3-2.
The equipment’s power supply 1 complies with IEC/EN 61000-3-3 and can be connected to current supply
network.
The equipment’s power supply 2 complies with IEC/EN 61000-3-2.
The equipment’s power supply 2 complies with IEC/EN 61000-3-3 and can be connected to current supply
network.
For model WH-MHF12G9E8:
The equipment’s power supply 1 complies with IEC/EN 61000-3-2.
The equipment’s power supply 1 complies with IEC/EN 61000-3-3 and can be connected to current supply
network.
The equipment’s power supply 2 complies with IEC/EN 61000-3-2.
The equipment’s power supply 2 complies with IEC/EN 61000-3-11 and shall be connected to suitable supply
network, with the following maximum permissible system impedance Z
max
= 0.449Ω per phase at the interface.
Please liaise with supply authority to ensure that the power supply 2 is connected only to a supply of that
impedance or less.
11.4.3 Wired Remote Control Installation
WARNING
Do not modify the length of the remote control cable. Otherwise, it will cause fire or electrical shock.
Be sure to turn off the main power before installing and connecting the remote control. Otherwise, it will cause the electrical shock.
Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, fire or electrical shock.
If passing the remote control cable through a wall, be sure to install a water trap above the cable. Otherwise, it will cause the
electrical shock.
CAUTION
Install in a flat surface to avoid warping of remote control, else damage to the LCD case or operation problems may result.
Avoid installing the remote control cable near refrigerant pipes or water pipes, else will cause electrical shock or fire.
Install the remote control cable at least 5 cm away from electric wires of other appliances to avoid miss operation (electromagnetic
noise).
Be sure to use only the accessory screws to avoid damage of remote control PCB.
Attached Accessories
No.
Name
Qty.
Diagram
Remark
(1)
Remote control
1
(2)
Remote control cable
1
Length (15 m)
(3)
Screw
(M4 machine pitched - 30 mm)
3
Installing the remote control to an outlet box
(embedded cable)
(4)
Screw
(M4 self-tapping - 14 mm)
3
Installing the remote control to the wall
(exposed cable)
Содержание WH-MHF09G3E8
Страница 32: ...32 10 1 2 Solar Printed Circuit Board Optional ...
Страница 33: ...33 10 2 Refrigerant System 10 2 1 Main Printed Circuit Board ...
Страница 34: ...34 10 2 1 1 Noise Filter Printed Circuit Board ...
Страница 47: ...47 Heat Mode Operation Time Chart ...
Страница 49: ...49 ...
Страница 50: ...50 ...
Страница 56: ...56 ...
Страница 57: ...57 ...
Страница 58: ...58 ...
Страница 127: ...127 17 3 To Remove The Cabinet Rear Plate 17 4 To Remove Pressure Gauge 17 5 To Remove RCCB ...
Страница 134: ...134 6 25 68 30 5 2 9 7 8 4 27 1 3 21 23 26 62 8 75 24 71 49 48 20 13 12 10 11 4 15 77 71 13 15 78 14 ...
Страница 138: ...138 19 2 Water System 44 46 17 16 4 34 42 18 43 3 33 9 1 45 45 47 2 35 48 36 19 ...