45
2-3-4 Working field and center position
q
e
r
t
t
w
Specified point
Model
VL-W1500
VL-W1A00
VL-W1506
VL-W1A06
q
Center position of laser emission port
81.5 mm
w
Center position of laser emission port
109 mm
e
Work distance (base position)
315 mm
685 mm
r
Work distance (setting range)
± 15 mm
t
Working field (X, Y)
200 mm x 200 mm
400 mm x 400 mm
ワㄐㄕㄊㄆ
• Do not place anything in the area between the laser emission port and lasing object during the lasing operation.
• Use anti-reflection material (ex. black paint for metal) for an external shutter or a protective enclosure in a path of laser
beam. It may cause a failure of the components inside the head.
• If any other devices such as a sensor or a camera are installed near the laser processing machine, make sure that these
devices are installed in the place where laser beam and its reflected beam do not damage to them.