172
ERROR
CODE
Description
Measures *
E613
Precompiled mode is not available for this
drawing data.
• Change Data compile mode to “Runtime” in File option
menu.
• To use Precompiled mode, speed up scanning speed.
E614
SEO command is not available with
Precompiled mode.
• To use SEO command, change Data compile mode to
“Runtime” in File option menu.
• To use Precompiled mode, disable “Offset by SEO
command” in File option menu.
E650
Invalid setting in custom shape elements.
• For arc shape, set the distance between the start point and
end point to less than double for radius.
• For rectangle shape, set the height or width to more than
double for fillet radius.
E651
Invalid line length in custom shape
elements.
Set the distance between start point and end point of a line
more than 0.01 mm.
E660
Cannot read DXF file.
• Import the DXF file again on the data management screen.
• Save the DXF file with DXF-R12J, R13J or R14 format.
• Delete the entities which are not supported by laser
processing machine in the DXF file.
• Reduce the number of layers to 128 or less.
E690
Measurement time over: Over 9999 sec.
• Reduce the number of segments in the drawings and
measure the time.
• Speed up scanning speed.
E700
Unable to lase as laser pumping is turned
OFF.
• Turn ON the laser supply and after the laser pumping has
completed, start lasing.
• Change timing so that the lasing trigger is input after the
laser supply input is turned ON.
• Check wiring of I/O or communication port to the external
control devices.
• Check the procedures and operation logic of laser pumping
(laser supply) control.
E710
Laser energy is out of threshold.
• Check the setting value of thresholds.
• If there is a decrease in lasing quality, check the output
power.
E720
Lasing pause was detected due to data
compiling during operation.
It might affect the processing results.
• To avoid lasing pause, set Data compile mode to
Precompiled in File option menu.
• To use Runtime mode, decrease scanning speed.
• If the processing results are not impaired by lasing pause, it
is possible to use Runtime mode. In such case this warning
can be disabled by selecting “Disable warning E720” at
Data compile mode setting.
E730
TRIGGER IN turned off before the
minimum number of scans was reached.
• Confirm the on/off control of the TRIGGER IN on the I/O
terminal.
• If TRIGGER IN turns on/off properly, change the setting
value of Minimum number of scans in File option menu.
E731
Lasing stopped because the maximum
number of scans was reached.
• Confirm the on/off control of the TRIGGER IN on the I/O
terminal.
• If TRIGGER IN turns on/off properly, change the setting
value of Maximum number of scans in File option menu.
ME-VLW1-SM-8
Содержание VL-W1 Series
Страница 18: ...1 Product Overview ME VLW1 SM 8...
Страница 40: ...2 Laser Processing Machine Installation ME VLW1 SM 8...
Страница 64: ...3 Operation Method ME VLW1 SM 8...
Страница 82: ...4 External Control Using I O ME VLW1 SM 8...
Страница 122: ...5 External Control by Communication Commands ME VLW1 SM 8...
Страница 129: ...6 Laser Power Monitoring Function ME VLW1 SM 8...
Страница 142: ...7 Maintenance ME VLW1 SM 8...
Страница 159: ...Troubleshooting ME VLW1 SM 8...
Страница 174: ...Index ME VLW1 SM 8...
Страница 177: ......