79
DHW PAW-VP - Installation manual – 2020-05
Electrical Heater
10
Also, the other information can be seen on the display. All reminders and their description are
specified in the following table:
Information
displayed
Acoustic
alarm
Alarm diode
Description
Variable
Flashing
Lack or failure of the sensor. Alarm switches off
automatically after repair of the failure.
Variable
Flashing
Exceeding of the maximum temperature (75 °C,
95 °C, 110 °C) (
Pro
tect). Alarm is switched off after
manual deleting (entering the off switching mode).
Interrupted
Flashing
Detection of lack of water (
No L
iquid). Alarm is
switched off after manual deleting (entering the off
switching mode).
Interrupted
Flashing
Detection of lack of heating (
No H
eating). Alarm is
switched off after manual deleting (entering the off
switching mode).
—
—
Input of the external control
EXT
opened.
Controller stops the function of heating.
The menu is divided into two sections: the operational menu (the unit in the ON mode) and the
service menu (unit in the OFF mode).
Operational Menu (Controller in ON Mode, see also sec.10.3.3 auf Seite 81)
Function name
Parameter
Setting ranges
Factory setting
Setting of heating
temperature
15–160 °C*
50 °C**
Setting of temperature
hysteresis
1–10 °C*
°C**
* Depending on the maximum heating temperature programmed in the controller.
** Factory settings are only the proposals for a setting. All the values depend on the size of heaters, the
capacity of the tank, user requirements etc.
Service Menu (Controller in OFF Mode, see also sec. 10.3.4 auf Seite 81)
Function name
Parameter
Setting ranges
Factory setting
Setting of heating
detection
0 and 1
1