Electrical Heater
10
10.2 Model PAW-VP380L
For the above mentioned heating or cooling tank, the electrical auxiliary heater is an optional
component and must be ordered separately on request.
It can be useful, for example, when particularly low outside temperatures are expected or to
compensate for maintenance interruptions.
Heater for
Voltage
Capacity
PAW-VP380L
400 V (L1 / L2 / L3 / N /PE / 50Hz)
6 kW
10.2.1 Installation of the Heating Unit
How to Mount the Heating Unit
Proceed as follows:
1. Screw the heating unit (
A
) into the unit seat (ensure the appropriate tightness of
the connection)
2. Unscrew the upper part of the box (
B
)
3. Connect the supplying cables to appropriate power connections situated in the up-
per part of the box (
B
) in accordance with the diagram for connecting three or one
phase heaters (see item
10.2.2 „Electrical Connection“ on page 77
4. Assemble the upper part of the box with the rest of the heating unit