26
DHW PAW-VP - Installation manual – 2020-05
Water Piping Installation
3
3.3 Filling Procedure
● DO NOT turn on any heat source connected to the storage tank until it is filled, it can
result in catastrophic damage.
●
Ensure that all installation requirements, electrical and safety, have been met.
●
Check all plumbing and electrical connections are properly connected.
●
Make sure that unused connections are closed with sealing plugs.
● Open the bleed valve on the set which is connected to the tank and start filling slowly.
● Let the unit fill, checking the bleeding air from the open tap; let out of the water to allow
the flushing of the pipes.
●
Close the bleed valve.
●
Open the any water sources (e.g. taps), to eliminate residual air in the system.
●
Close all the water outlets and check for water leaks in the system.
●
Fill any circuits connected to the tank.
●
Test manually the pressure regulating valve and the safety valves on each hydraulic
circuit.
3.4 Emptying Procedure
●
Isolate any electrical supplies to the heat source.
●
Disconnect the water supply to the tank.
●
Open a bleed valve on the set connected to the tank to allow the entry of air into the
system.
●
Open the discharge of the system. Please pay close attention and care with the water dis-
charged from the system, as it could cause damage to property or persons.
3.5 Maintenance Procedure
●
Check periodically (at least once a year) the smooth operation of the safety valve.
●
In accumulations of DHW always install a passive cathodic protection (magnesium
anode) or active (impressed current anode) and check periodically, at least twice a year,
observe wear of a sacrificial magnesium anode or the presence of power supply on the
anode impressed current; an anode of magnesium consumed more than 60% should be
replaced.
●
Inspect all water connections for leakage every year.
● Dismantle the flange with the DHW heater and clean the bottom tank internally every
other year if the water quality is poor.
●
Test safety thermostat and check electrical connections for DHW heater every year.
●
Leak search refrigerant connections at the top of the tank for heat pump every year.
●
Leak search refrigerant hose from double coil every year.
●
Inspect the coil and clean it if necessary every other year.
●
Test run the heat pump and check sensor info parameters.
●
Check outdoor unit procedures referenced to the service manual for outdoor unit.