83
DHW PAW-VP - Installation manual – 2020-05
Appendix
A
A Appendix
A.1 U.K. Accessories: PAW-G3KITL
Please check and follow local regulations!
For the United Kingdom, please follow the Water Supply Water Fitting Regulation, WRAS
requirements. For use with PAW-VP1000LDHW-1 or PAW-VP750LDHW-1 the optional PAW-
G3KITL may be utilised to fulfil the local regulation.
Components supplied with the unit in a separate accessory kit* (PAW-G3KITL) for site fitting:
● Multiblock valve, includes pressure reducing valve, line strainer, balanced cold
water take off, (for shower or bidet only) check and expansion valve.
●
Tundish - 1 1/4" × 1 1/2"
● 22mm x 1" Elbow / Drain Cock
● Motorised valve
● Expansion vessel.
* Only valid for UK can be ordered separately if required
Installation example
City water inlet
A
Pressure reducing valve
Multiblock (2.1 bar) includes
Expansion valve (8 bar)
B
Expansion vessel
C
Temperature and pressure
relief valve
D
Tundish
E
Elbow / Drain cock
C
"Temperature and pressure relief valve" is factory fitted for tank
versions PAW-VP1000LDHW-1 or PAW-VP750LDHW-1
A
B
C
D
E