2.9.
Fuser Unit (431), Fuser Lamp (408), Thermistor Assembly (405), Paper
Exit Sensor (610)
(1) Remove the Left Side Cover (107) (Refer to 2.3.).
(2) Disconnect 2 Connectors.
(3) Disconnect the Relay Connector.
(4) 1 Screw (19).
(5) Remove the Ground Strap (653).
(6) 3 Screws (4N).
(7) Remove the Fuser Unit (431).
(8) 1 Screw (23).
(9) Remove the Fuser Lamp Terminal C (404).
(10) Remove the Fuser Lamp (408).
Caution:
When re-installing the Fuser Lamp, make sure that the
Fuser Lamp is inserted into the Fuser Unit as illustrated
on the left.
Do not touch the glass portion of the Fuser Lamp with
bare hands. Grease from the fingerprints will shorten its
life cycle, use isopropyl alcohol to clean fingerprints.
(11) 1 Screw (1Q).
(12) Disconnect Connector.
(13) Remove the Thermistor Assembly (405).