208
Fuser Error Detection
215
210
200
190
180
172
70
25
14
( C)
193
185
ON
OFF
Approx. 30sec
Time
E26 will be logged.
(Thermal Fuse will open.)
E24 will be logged if Thermistor detects 210 C
for more than 3 sec. (Thermostat will open.)
Fan speed rotates slower if Thermistor detects
less than 150 C for 60 sec, after Fuser Lamp is
turned Off.
E23 will be logged if Thermistor
detects 197 C or higher for 5 min.
after Fuser Lamp is turned Off.
Fan stops if Thermistor detects less than
70 C for 225 sec after Fuser Lamp is
turned Off.
E24 will be logged if
Thermistor detects less
than 170 C for 3 sec during
the print process.
E22 will be logged when
temperature does not rise.
E25 will be logged when
temperature does not go up
at low temperature
environment.
Fan rotates high speed
Fuser Roller Temperature