No. SX-DSV03015 - 42 -
Motor Business Unit, Panasonic Corporation
*) Dynamic brake
Servo driver(size A-F) has built-in dynamic brake function to stop motor in an emergency.
Dynamic brake can be operated in the following cases
1. The main power off
2. The servo off
3. Protection action
4. Connector X4 driving ban importation (POT, NOT) action
On the above 1~4 cases, valid or invalid of dynamic brake can be determined by the parameters.
However, when the control power off, dynamic brake of size A-F keep valid condition.
Dynamic brake shall be using in rated short time for emergency stop using. Please note the following points.
1. Do not start / stop the motor by the servo signal (SRV-ON) . Built-in dynamic brake circuit may be damaged.
2. Do not drive the motor with external torque. Motor generates electricity by external torque.
Dynamic brake circuit will be damaged and it is possible that short-circuit current cause smoke or combustion.
3. Allow approx. 10 minutes pause when the dynamic brake is activated during high-speed running.
Resistor is damaged and the dynamic brake might not work when using it under more critical operating
condition.
*) Mounting direction and spacing
-To perform effective cooling, allow sufficient ambient space.
-Provide a fan so as to make uniform the temperature in the control panel.
-Each of Sizes D to F is equipped with a cooling fan on the bottom.
-Adhere to environmental conditions for the environment in the control panel.
d
d
d
Fan
Fan
100mm
or more
Direction of air flowing from
the internal cooling fan (Sizes D – F)
Control panel
40mm
or
more
40mm
or
more
100mm
or more
In case the portion to receive a fan is coated, peeling off the coating before installing a fan or using homebuilt bracket
s with conductive plating provides effective anti-noise measures.
d
Sizes A-F
10 mm or more