No. SX-DSV03015 - 13 -
Motor Business Unit, Panasonic Corporation
[3] Size E of 200 V system
Connector
pin No.
Terminal
symbol
Name
Description
XA
5
L1
Main power supply
input
200 V
3 phase 200 - 240 V
+ 10 %
- 15 %
50/60 Hz input
4
L2
3
L3
2
L1C
Control power
supply input
200 V
Single phase 200 - 240 V
+ 10 %
- 15 %
50/60 Hz input
1
L2C
XC
4
P
Regen resistor
connection
Normally, short out the circuit between RB and B.
When a trip happens due to a regenerative load protection error, open the
circuit between RB and B and connect an external regenerative resistor
(prepared by customer) between P and B.
Then, specify the external regenerative resistor for parameter Pr0. 16.
Do not connect N terminal.
3
RB
2
B
1
N
XB
3
U
Motor connection
Connect each phase of the motor winding.
U: U phase V: V phase W: W phase
2
V
1
W
Earth
Earth terminal for grounding
* Tighten the earth screws M4 with the 0.7-0.8 Nm torque respectively.