No. SX-DSV03015 - 36 -
Motor Business Unit, Panasonic Corporation
8-3 Precautions for wiring
(1) Wiring to power connector and terminal block
100/ 200 V sizes A - B
L1
L2
L3
L
ON
MC1
OFF
ALM
Coli surge suppression units
L1C
L2C
P
MC
U
V
W
motor
ALM+
ALM-
ALM
Main power
supply
Control power
supply
Motor
connection
MCCB
37
36
Built-in thermostat of an external
regenerative resistor (light yellow)
B
Red
White
Green or
Green/Yellow
Insulated
DC12 to 24 V
(
±
5 %)
+
-
N
oi
s
e f
ilt
er
N
External
regenerative
resistor
XA
XB
X4
*When you use single phase,
connect the main power
between L1 and L3 terminals.
Power supply
(3-phase)
Black
■Connection of regenerative resistor
Size
Shorting
cable
(Accessories)
Internal
regenerative
resistor
Connection of the connector XB
In case of using the external
regenerative resistor
In case of not using the external
regenerative resistor
A
B
Not attached
Not
installed
Between P and B:
Connect the external
regenerative resistor.
Between P and B:
Keep open
- The circuit connected to terminal X1 – X6 are secondary circuits.
Insulation is needed against the primary side power supply (power supply of the motor brake).
Please do not connect them with the same power supply.