4. Communication
Specifications
/LVWRI8VHU3DUDPHWHUVIRU&RPPXQLFDWLRQ
Class No.
Title
Setup
value
Function
5
31 Axis address
0 to
127
Set the axis number for serial communication to 0 to 31.
This parameter setup value has no effect on servo operation.
5
29
Baud rate
setup of RS232
communication
0 to
6
Set up the communication speed of RS232 communication.
0 : 2400[bpps], 1 : 4800[bps], 2 : 9600[bps], 3 : 19200[bps],
4 : 38400[bps], 5 : 57600[bps], 6 : 115200[bps]
8SGDWHGVHWXSRILVYDOLGDWHGXSRQWXUQLQJRQRIFRQWUROSRZHU
5
30
Baud rate
setup of RS485
communication
0 to
6
Set up the communication speed of RS485 communication.
0 : 2400[bpps], 1 : 4800[bps], 2 : 9600[bps], 3 : 19200[bps],
4 : 38400[bps], 5 : 57600[bps], 6 : 115200[bps]
8SGDWHGVHWXSRILVYDOLGDWHGXSRQWXUQLQJRQRIFRQWUROSRZHU
5HTXLUHGWLPHIRUGDWDWUDQVPLVVLRQSHUE\WHLVFDOFXODWHGLQWKHIROORZLQJIRUPXODLQ
case of 9600[bps].
1000 / 9600 × (1 + 8 + 1 ) = 1.04 [ms/byte]
Start bit
Stop bit
Data
Note that the time for processing the received command and time for switching the line
and transmission/reception control will added to the actual communication time.
Caution
+DQGVKDNHFRGH
Following codes are used for line control.
Title
Code
Function
ENQ
05h (Module recognition byte of the transmitted)
Enquire for transmission
EOT
04h (Module recognition byte of the transmitted)
Ready for receiving
ACK
06h
Acknowledgement
NAK
15h
Negative acknowledgement
ENQ ..... The module (host or driver) sends out ENQ when it has a block to send.
EOT ..... The module (host or driver) sends out EOT when it is ready to receive a
block. The line enters to a transmission mode when ENQ is transmitted and
EOT is received.
ACK ..... When the received block is judged normal, the module (host or driver) will
send out ACK.
NAK ..... When the received block is judged abnormal, NAK will be sent. A judgment is
based on checksum and timeout.
1 byte of module recognition is added to ENQ and EOT at RS485 communication.
Module recognition byte... Make the Pr5.31 value of the front panel as a module ID,
and data which makes its bit7 as 1, becomes a module recognition byte.
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
1
0
0
0
Module ID
Module ID : The module ID of the host side will be 0 in case of RS485 communica-
tion, therefore set up Pr5.31 of MINAS-A5 to 1 to 31.
Note
2QO\IRUSRVLWLRQFRQWUROW\SHLVQRWSURYLGHGZLWK;&RPPXQLFDWLRQFRQQHFWRUDQG;&RQ
-
nector for External Scale).
2QO\IRUSRVLWLRQFRQWUROW\SHGRHVQRWVXSSRUWWKHELWDEVROXWHVSHFLÀFDWLRQ
,WVXSSRUWVRQO\ELWLQFUHPHQWDOVSHFLÀFDWLRQ
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Содержание MINAS A5 Series
Страница 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...