2-47
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
Power supply 3-phase, 380V to 480V
–15%
+10%
Note 1)
Shielding the circuit is recommended for the purpose of noise reduction.
Note 2)
Magnetic contactor MC2 must be the same as the contactor MC1 in the main circuit.
Note 3)
Servo may be turned on in the external sequence if the dynamic brake resistor deposits: to protect the
system, provide the auxiliary contact.
Note 4)
Use 4.8
ї
, 400 W resistor (to be supplied by customer).
Note 5)
To use the external dynamic brake resistor:
Connect the R1 and R2 terminals to B1 and B2.
Connect the T1 and T2 terminals as shown in the left diagram.
Connect the 24 V and 0 V terminals to a 24 VDC power supply.
Connect the E terminal to the ground.
Refer to P.7-122 “Options” for the specifications of the external regenerative resistor.
Note 6)
Provide an external protective device (e.g. thermal fuse) to monitor the temperature of the external
dynamic brake resistor.
Noise filter
Main power
supply
Control power
supply
Motor
37
ALM
+
L2
L3
24V
0V
MC1
MC2
L1
ALM
−
MCCB
Motor
connection
Power supply
(3-phase)
Power supply
(
Neutral point
)
The AC voltage across
DB1 and DB2 must be
300 V or below.
36
L
ON
ALM
B1
B2
NC
DB1
DB2
U
V
W
ALM
OFF
Coil surge suppression units
Coil surge suppression units
Built-in thermostat of
an external regenerative
resistor
(T1 and T2 terminals)
Dynamic Brake resistor
Note 4)
Note 3)
MC2
Note 1)
MC1
Note 5)
Note 1)
External
regenerative resistor
Note 6) Note 6) Note 6)
Insulated
DC12 to 24V
(±5%)
+
ï
Insulated
DC24V
+
ï
Insulated
DC24V
+
ï
Compose the circuit so that the main circuit power will be shut off when an error occurs.
In Case of 3-Phase, H-frame, 400 V type
2
Preparation
2.
6\VWHP&RQÀJXUDWLRQDQG:LULQJ
Wiring Diagram (H-frame, 400 V type)
Note
Related page
The wiring indicated with the broken line shall be provided only when required.
3´6SHFLÀFDWLRQVRI0RWRUFRQQHFWRUµ
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Содержание MINAS A5 Series
Страница 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...