Below shows the composition of data block which is transmitted in physical phase.
N
: Command byte counts (0 to 240)
Shows the number of parameters which are required by command.
axis
: Sets up the value of Pr5.31.(0 to 127)
command : Control command (0 to 15)
mode
: Command execution mode (0 to 15)
Contents vary depending on the mode.
check sum : 2's complement of the total number of bytes, ranging from the top to the
end of the block
3URWRFRO3DUDPHWHU
Following parameters are used to control the block transmission. You can set any
value with the INIT command (described later).
Title
Function
Initial value
Setup range
Unit
T1
Time out between characters
RS232
5 (0.5 sec)
1 to 255
0.1 sec
RS485
1 (0.1 sec)
T2
Protocol time out
RS232
5 (0.5 sec)
1 to 255
1 sec
RS485
1 (0.1 sec)
T6
Driver response time
RS232
0 (0ms)
0 to 255
1 ms
RS485
6 (6ms)
2 to 255
RTY
Retry limit
1 (once)
1–8
Once
M/S
Master/Slave
0 (Slave)
0, 1 (Master)
7 3HUPLVVLEOH WLPH LQWHUYDO IRU WKLV GULYHU WR UHFHLYH WKH FRQVHFXWLYH FKDUDFWHU FRGV ZKLFK H[LVWV
between the module recognition bytes and ENQ/EOT, or in the transmission/reception data
block. Time out error occurs and the driver returns NAK to the transmitter when the actual recep-
tion time has exceed ed this setup time.
7 3HUPLVVLEOHWLPHLQWHUYDOIRUWKHGULYHUWRWUDQVPLW(14DQGWRUHFHLYH(27,IWKHDFWXDOUHFHS
-
tion time exceeds this setup, this represents that the receiver is not ready to receive, or it has
failed to receive ENQ code in some reason, and the driver will re-transmit ENQ code to the re-
ceiver. (retry times)
3HUPLVVLEOH WLPH LQWHUYDO IRU WKH GULYHU WR WUDQVPLW (27 DQG WR UHFHLYH WKH UHFHSWLRQ RI WKH VW
FKDUDFWHUFRGH7KHGULYHUZLOOUHWXUQ1$.DQGÀQLVKHVWKHUHFHSWLRQPRGHLIWKHDFWXDOUHFHSWLRQ
has exceeded this setup time.
3HUPLVVLEOH WLPH LQWHUYDO IRU WKH PRGXOH WR WUDQVPLW WKH FKHFN VXP E\WHV DQG WR UHFHLYH$&.
The module will re-transmit ENQ code to the receiver in the same way as the NAK reception, if
the actual reception time exceeds this setup time.
7 3HUPLVVLEOH WLPH LQWHUYDO IRU WKH GULYHU WR UHFHLYH (14 DQG WR WUDQVPLW (27 3HUPLVVLEOH WLPH
LQWHUYDOIRUWKHGULYHUWRUHFHLYHWKHFKHFNVXPE\WHVDQGWRWUDQVPLW$&.DQG3HUPLVVLEOHWLPH
interval for the driver to receive EOT and to transmit the 1st character.
RTY: Maximum value of retry times. Transmission error occurs if the actual retry has exceeds this setup
value.
M/S: Switching of master and slave. When contention of ENQ has occurred, the module decides which
is to be given priority.
Priority is given to the transmitter which is set up as a master. (0: Slave mode, 1 : Master mode)
N
axis
Parameter
(N byte)
check sum
(1 byte)
command
mode
4. Communication
Specifications
Note
2QO\IRUSRVLWLRQFRQWUROW\SHLVQRWSURYLGHGZLWK;&RPPXQLFDWLRQFRQQHFWRUDQG;&RQ
-
nector for External Scale).
2QO\IRUSRVLWLRQFRQWUROW\SHGRHVQRWVXSSRUWWKHELWDEVROXWHVSHFLÀFDWLRQ
,WVXSSRUWVRQO\ELWLQFUHPHQWDOVSHFLÀFDWLRQ
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Содержание MINAS A5 Series
Страница 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...