2-23
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
Motor
37
ALM+
L2
L3
L1C
L2C
MC
MCCB
L1
$/0ï
X4
Terminal block
36
L
ON
ALM
B1
B3
B2
NC
U
V
W
ALM
OFF
Built-in thermostat of
an external regenerative
resistor (light yellow)
MC
Noise filter
External regenerative resistor
(Remove the short wire when you connect
the external regenerative resistor.)
Main power
supply
Control power
supply
Motor
connection
Power supply 3-phase, 200V to 230V
–15%
+10%
Red
White
Black
Green
Coil surge suppression units
* These colors
are used for
optional cable.
Insulated
DC12 to 24V
(±5%)
+
ï
Compose the circuit so that the main circuit power will be shut off when an error occurs.
In Case of 3-Phase, F-frame, 200 V type
2
Preparation
2.
6\VWHP&RQÀJXUDWLRQDQG:LULQJ
Wiring Diagram (F-frame, 200 V type)
Note
Related page
The wiring indicated with the broken line shall be provided only when required.
3´6SHFLÀFDWLRQVRI0RWRUFRQQHFWRUµ
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Содержание MINAS A5 Series
Страница 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...