2-79
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
Parametr
No.
Title
Range
Default
Unit
Turning
on of
power
supply
Related
Control Mode Detail
page
Class No.
A,B
-frame
C
-frame
D,E,F
-frame
G,H
-frame
P
S
T
F
4
30
Analog input 3 (AI3) overvoltage
setup
0 to 100
0
0.1V
*
○ ○ ○ ○
4-39
4
31
Positioning complete (In-position)
range
0 to 262144
10
Command
unit
○
○
4
32
Positioning complete (In-position)
output setup
0 to 3
0
ï
○
○
4
33
INP hold time
0 to 30000
0
1ms
○
○
4
34
Zero-speed
10 to 20000
50
r/min
○ ○ ○ ○
4-40
4
35
Speed coincidence range
10 to 20000
50
r/min
○
4
36
At-speed (Speed arrival)
10 to 20000
1000
r/min
○ ○
4-41
4
37
Mechanical brake action at stalling
setup
0 to 10000
0
1ms
○ ○ ○ ○
4
38
Mechanical brake action at running
setup
0 to 10000
0
1ms
○ ○ ○ ○
4
39
Brake release speed setup
30 to 3000
30
r/min
○
○ ○ ○ ○
4-42
4
40
Selection of alarm output 1
0 to 10
0
ï
○ ○ ○ ○
4
41
Selection of alarm output 2
0 to 10
0
ï
○ ○ ○ ○
4
42
2nd Positioning complete (In-position)
range
0 to 262144
10
Command
unit
○
○
'HÀQLWLRQRIV\PEROVXQGHU´3RZHU2II2QµLIDFKDQJHLVPDGHLWZLOOEHUHÁHFWHGXSRQWKHSDUDPHWHUZKHQWKH
power to the driver is turned off and then on again.
*
'HÀQLWLRQRIV\PEROVXQGHU´5HODWHGPRGHµ3SRVLWLRQFRQWURO6YHORFLW\FRQWURO7WRUTXHFRQWURO)IXOOFORVHGFRQWURO
[Class 5] Enhancing setting
Parametr
No.
Title
Range
Default
Unit
Turning
on of
power
supply
Related
Control Mode Detail
page
Class No.
A,B
-frame
C
-frame
D,E,F
-frame
G,H
-frame
P
S
T
F
5
00
2nd numerator of electronic gear
0 to 2
30
0
ï
○
○
4-43
5
01
3rd numerator of electronic gear
0 to 2
30
0
ï
○
○
5
02
4th numerator of electronic gear
0 to 2
30
0
ï
○
○
5
03
Denominator of pulse output division 0 to 262144
0
ï
○
○ ○ ○ ○
5
04
Over-travel inhibit input setup
0 to 2
1
ï
○
○ ○ ○ ○
5
05
Sequence at over-travel inhibit
0 to 2
0
ï
○
○ ○ ○ ○
5
06
Sequence at Servo-Off
0 to 9
0
ï
○ ○ ○ ○
4-44
5
07
Sequence at main power OFF
0 to 9
0
ï
○ ○ ○ ○
5
08
LV trip selection at main power OFF
0 to 1
1
ï
○ ○ ○ ○
4-45
5
09
Detection time of main power off
70 to 2000
70
1ms
○
○ ○ ○ ○
'HÀQLWLRQRIV\PEROVXQGHU´3RZHU2II2QµLIDFKDQJHLVPDGHLWZLOOEHUHÁHFWHGXSRQWKHSDUDPHWHUZKHQWKH
power to the driver is turned off and then on again.
*
'HÀQLWLRQRIV\PEROVXQGHU´5HODWHGPRGHµ3SRVLWLRQFRQWURO6YHORFLW\FRQWURO7WRUTXHFRQWURO)IXOOFORVHGFRQWURO
13. Setup of Parameter and Mode
List of Parameters
Note
Parameter describes of this page is P.4-39 to P.4-45.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Содержание MINAS A5 Series
Страница 164: ...2 116 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 280: ...4 64 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 322: ...5 42 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 350: ...6 28 MEMO Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...