2.2 Programming
Programming Guide
15
Parameter Descriptions
The parameters indicated with "
#
" must be changed while the VoIP Gateway Card is in the "STOP" status (see
"2.3.1 Status Control"). The changes must be followed by a reboot to become effective (see "2.5.1 Reboot").
The parameters indicated with "
*
" must be changed while the card is in the "STOP" status (see "2.3.1 Status
Control"). The changes do not have to be followed by a reboot to become effective.
Port No. Settings
Parameter & Description
Default
Value Range
#
H.225 Port No.
Specifies the port number for the H.225 protocol (call control)
in an H.323 protocol suite.
Generally, there is no need to change the default value.
1720
1 to 65535
#
H.245 Port No.
Specifies the port number for the H.245 protocol (negotiation
of channel usage and capabilities) in an H.323 protocol suite.
32 consecutive ports, starting with the specified port, will be
used (by default, 1721 to 1752).
Generally, there is no need to change the default value.
1721
1 to 65504
#
RAS Port No.
Specifies the port number for the H.225 protocol (RAS) in an
H.323 protocol suite.
Generally, there is no need to change the default value.
1719
1 to 65535
#
RTP/RTCP Port No.
Specifies the port number for RTP/RTCP. 64 consecutive
ports, starting with the specified port, will be used (by default,
5004 to 5067).
Generally, there is no need to change the default value.
5004
1 to 65472
Содержание KX-TDA0490
Страница 4: ...4 Getting Started ...
Страница 20: ...2 2 Cable Connection 20 Getting Started ...
Страница 45: ...Getting Started 45 Appendix A Guidance for VoIP Installation ...
Страница 55: ...Getting Started 55 Appendix B Alternative Numbering Plan Example ...
Страница 63: ...Getting Started 63 Appendix C Initialisation of the VoIP Gateway Card ...
Страница 66: ...C1 Initialising the VoIP Gateway Card 66 Getting Started ...
Страница 67: ...Getting Started 67 Appendix D Using the KX TDA0490 and KX TDA0480 in One Network ...
Страница 69: ...D1 Considerations in Installation Getting Started 69 ...
Страница 76: ...1 1 Starting the IP GW16 Maintenance Utility 6 Programming Guide ...
Страница 125: ...2 5 Others Programming Guide 55 2 5 2 Log Out 1 Click LOGOUT in the main menu 2 Click OK to log out ...
Страница 126: ...2 5 Others 56 Programming Guide ...
Страница 138: ...3 4 Others 68 Programming Guide 3 4 2 Log Out 1 Click LOGOUT in the main menu 2 Click OK to log out ...
Страница 139: ...Programming Guide 69 Index ...