2.2 Programming
Programming Guide
21
Gain Level Settings
The parameters below are used to adjust the gain level. However, in general, there is no need to change the
default values.
Voice Activity Detection (VAD) Settings
Others
Parameter & Description
Default
Value Range
Gain Level PCM
→
LAN (dB)
Specifies the gain level (in decibels) output from the PBX,
through the card, to the LAN.
0
-14 to 6
Gain Level LAN
→
PCM (dB)
Specifies the gain level (in decibels) output from the LAN,
through the card, to the PBX.
0
-14 to 6
Parameter & Description
Default
Value Range
G.723.1/G.729A/G.711 VAD
Specifies the use of the VAD feature for each available
CODEC (G.723.1, G.729A, and G.711).
The VAD conserves bandwidth by detecting silent periods
during a call and suppressing the packets of silence from
being sent to the network.
Notes
•
To use the VAD feature for a certain CODEC, be
sure to enable it for that CODEC on both the local
and remote cards.
•
To use the VAD feature between the KX-TDA0490
and KX-TDA3480/KX-TDA0484, you must enable it
for the G.723.1 CODEC. Otherwise, the VAD feature
cannot be used between these cards (although calls
can be made and received as normal).
Use
Use,
Don't use
Parameter & Description
Default
Value Range
G.723.1 Rate
Specifies the rate of the G.723.1 CODEC.
6.3Kbps
5.3Kbps,
6.3Kbps
DTMF Detection
Specifies the use of the DTMF detection feature.
DTMF detection enables end-to-end DTMF relay over the
network.
For details, refer to "Detailed Explanations".
Use
Use,
Don't use
Содержание KX-TDA0490
Страница 4: ...4 Getting Started ...
Страница 20: ...2 2 Cable Connection 20 Getting Started ...
Страница 45: ...Getting Started 45 Appendix A Guidance for VoIP Installation ...
Страница 55: ...Getting Started 55 Appendix B Alternative Numbering Plan Example ...
Страница 63: ...Getting Started 63 Appendix C Initialisation of the VoIP Gateway Card ...
Страница 66: ...C1 Initialising the VoIP Gateway Card 66 Getting Started ...
Страница 67: ...Getting Started 67 Appendix D Using the KX TDA0490 and KX TDA0480 in One Network ...
Страница 69: ...D1 Considerations in Installation Getting Started 69 ...
Страница 76: ...1 1 Starting the IP GW16 Maintenance Utility 6 Programming Guide ...
Страница 125: ...2 5 Others Programming Guide 55 2 5 2 Log Out 1 Click LOGOUT in the main menu 2 Click OK to log out ...
Страница 126: ...2 5 Others 56 Programming Guide ...
Страница 138: ...3 4 Others 68 Programming Guide 3 4 2 Log Out 1 Click LOGOUT in the main menu 2 Click OK to log out ...
Страница 139: ...Programming Guide 69 Index ...