Symptom
Cause
Solution
Reference
page
The receiver of the sensor
head is receiving ambient
light from surrounding
photoelectric sensors,
inverters, or other devices.
Mount a shielding plate to prevent ambient
light from hitting the receiver of the sensor
head. Mount a shielding plate at a certain
angle to the sensor head.
-
Dust, grit, or other
substances are flying in the
operating environment.
Use a dust collector or similar device to
remove and prevent dust, grit, and other
substances from flying in the operating
environment.
-
The sensor head is installed
in a location subject to severe
vibration.
Take measures against vibration.
-
Mutual interference is
occurring.
Set the interference prevention function to
ON.
The distance between the
installed emitter and receiver
exceeds the specified range.
Ensure that the distance between the
installed emitter and receiver is within the
specified range.
The distance between the
sensor head receiver and the
measured object is too far.
Make the distance between the installed
emitter and receiver as short as possible.
-
The serial number of the
emitter differs from that of the
receiver.
Use a pair of emitter and receiver with the
same serial number.
-
Judgment value
shifts
The reference waveform is
not registered correctly.
After adjusting the beam axis, register the
reference waveform.
The measured object is
inclined relative to the
measurement range.
Place the measured object in the correct
position.
-
The distance between the
installed emitter and receiver
exceeds the specified range.
Ensure that the distance between the
installed emitter and receiver is within the
specified range.
Dust, dirt, or other foreign
matters adhere to the light
emitting and receiving
surfaces of the sensor head.
To remove any dirt that adheres to the light
emitting and light receiving surfaces of the
sensor head, use compressed air or gently
wipe off using a clean, soft cloth.
If the surfaces are very dirty, wipe off dirt
using a cotton swab (or similar material)
moistened with absolute alcohol.
-
Dust, dirt, or other foreign
matters adhere to the
measured object.
Remove any dust, dirt, or other foreign
matters that adhere to the measured object.
-
The preset value is not set
correctly.
Specify the preset value correctly.
Analog scaling is not set
correctly.
Set analog scaling correctly.
Analog output is
not generated
correctly.
Analog output line is not
wired correctly.
Wire the analog output line correctly.
Keys cannot be
operated
The key lock function is ON.
Set the key lock function to OFF.
10.1 Troubleshooting
WUME-HGT-6
10-3
Содержание HG-T Series
Страница 2: ... MEMO 2 WUME HGT 6 ...
Страница 28: ... MEMO 2 8 WUME HGT 6 ...
Страница 96: ... MEMO 5 50 WUME HGT 6 ...
Страница 99: ... Note 2 Displayed only during calculation 6 1 Flow of Measurement Data WUME HGT 6 6 3 ...
Страница 128: ... MEMO 6 32 WUME HGT 6 ...
Страница 158: ... No timer OFF 7 2 Advanced Settings 7 30 WUME HGT 6 ...
Страница 177: ...Example Positioning a glass plate Setting method 7 2 Advanced Settings WUME HGT 6 7 49 ...
Страница 218: ...8 2 3 Side View Attachment HG TSV10 Units mm 8 2 Dimension Drawings 8 14 WUME HGT 6 ...
Страница 221: ...10 Troubleshooting 10 1 Troubleshooting 10 2 10 2 Error Messages 10 5 WUME HGT 6 10 1 ...
Страница 228: ...Menu Structure General Function Display Menu Structure General Function Display App 2 WUME HGT 6 ...
Страница 229: ...Menu Structure General Function Display WUME HGT 6 App 3 ...
Страница 230: ...Menu Structure Extended Function Display Menu Structure Extended Function Display App 4 WUME HGT 6 ...
Страница 231: ...Menu Structure Extended Function Display WUME HGT 6 App 5 ...
Страница 232: ... MEMO App 6 WUME HGT 6 ...
Страница 235: ... MEMO WUME HGT 6 ...
Страница 236: ...Panasonic Industrial Devices SUNX Co Ltd 2020 PRINTED IN JAPAN WUME HGT 6 ...