8.1.2 Sensor Head
Type
Measurement width 10 mm / Standard
type
Measurement width 10 mm / Slim type
Model No.
HG-T1010
HG-T1110
Position detection
method
CMOS-based
Installation distance
0 to 500 mm
Measurement width
10 mm
Light source
Red semiconductor laser: Class 1 [JIS / IEC / GB / FDA
]
Maximum output: 0.3 mW, Peak emission wavelength: 655 nm
Sampling cycle
1 ms (standard sampling) or 0.5 ms (high-speed sampling)
Repeatability
1 µm (Installation distance: 20 mm)
2.5 µm (Installation distance: 100 mm)
5 µm (Installation distance: 500 mm)
Linearity
±0.12% F.S (Installation distance: 20 mm)
±0.28% F.S (Installation distance: 100 mm)
Minimum sensing
φ0.5 mm (Installation distance: 500 mm)
Temperature
±0.03
%
F.S./°C
Protection
IP67 (IEC)(Excluding connectors)
Pollution degree
2
Ambient temperature
-10 to +45°C (No condensation or icing), Storage: -20 to +60°C
Ambient operating
humidity
35% to 85% RH, Storage: 35% to 85% RH
Ambient illuminance
Incandescent light: 5,000 ℓx or less at the light-receiving face
Elevation
2,000 m or lower
Insulation resistance
20 MΩ or higher, using 250 V DC megger (between all terminals and case)
Vibration resistance
10 to 55 Hz with 1.5 mm amplitude in X, Y and Z directions for two hours each
Shock resistance
196 m/s
2
in X, Y and Z directions three times each
Grounding method
Capacitor grounding
Materials
Case: Aluminum die casting, Light emitting and light receiving surfaces: Glass
Cable
0.2-m 4-conductor shielded cable with round connectors
Weight (main unit
only)
Emitter: Approx. 30 g, Receiver: Approx.
30 g
Emitter: Approx. 30 g, Receiver: Approx.
25 g
Standards compliance
EMC Directive, FDA
All the specifications shown above are based on the values that are digitally measured when the sensor head is
combined with controller
HG-TC
□.
This does not apply when Side View Attachment
HG-TSV10
(optional) is mounted.
Specification conditions that are not particularly specified are shown below.
● Ambient temperature: +20
℃
8.1 Specifications
WUME-HGT-6
8-9
Содержание HG-T Series
Страница 2: ... MEMO 2 WUME HGT 6 ...
Страница 28: ... MEMO 2 8 WUME HGT 6 ...
Страница 96: ... MEMO 5 50 WUME HGT 6 ...
Страница 99: ... Note 2 Displayed only during calculation 6 1 Flow of Measurement Data WUME HGT 6 6 3 ...
Страница 128: ... MEMO 6 32 WUME HGT 6 ...
Страница 158: ... No timer OFF 7 2 Advanced Settings 7 30 WUME HGT 6 ...
Страница 177: ...Example Positioning a glass plate Setting method 7 2 Advanced Settings WUME HGT 6 7 49 ...
Страница 218: ...8 2 3 Side View Attachment HG TSV10 Units mm 8 2 Dimension Drawings 8 14 WUME HGT 6 ...
Страница 221: ...10 Troubleshooting 10 1 Troubleshooting 10 2 10 2 Error Messages 10 5 WUME HGT 6 10 1 ...
Страница 228: ...Menu Structure General Function Display Menu Structure General Function Display App 2 WUME HGT 6 ...
Страница 229: ...Menu Structure General Function Display WUME HGT 6 App 3 ...
Страница 230: ...Menu Structure Extended Function Display Menu Structure Extended Function Display App 4 WUME HGT 6 ...
Страница 231: ...Menu Structure Extended Function Display WUME HGT 6 App 5 ...
Страница 232: ... MEMO App 6 WUME HGT 6 ...
Страница 235: ... MEMO WUME HGT 6 ...
Страница 236: ...Panasonic Industrial Devices SUNX Co Ltd 2020 PRINTED IN JAPAN WUME HGT 6 ...