Type
Master unit
Slave unit
High-performance type
Wire-saving type
Model No.
NPN
output
HG-TC101
HG-TC111
HG-TC113
PNP
output
HG-TC101-P
HG-TC111-P
Vibration resistance
10 to 150 Hz frequency, 0.75 mm double amplitude (10 to 58 Hz),
Maximum acceleration 49 m/s
2
(58 to 150 Hz) in X,Y and Z directions for two hours
each
Shock resistance
98 m/s
2
(approx. 10 G) in X, Y and Z directions 5 times each
Materials
Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Cable
0.2 mm
2
2-conductor
(brown and blue lead
wires) / 0.15 mm
2
7-
conductor 2m composite
cable
0.15 mm
2
7-conductor 2m
composite cable
―
Weight (main unit only)
Approx. 140 g
Approx. 140 g
Approx. 60 g
Standards compliance
EMC Directive
(Note 1)
Current consumption does not include analog current output.
(Note 2)
Linearity is a value calculated from digitally measured values at F.S. = 16mA for current output or F.S.
= 4 V for voltage output.
(Note 3)
When slave units are connected to the master unit, the maximum sink current and source current of
control output and ambient temperature vary depending on the number of connected slave units as
shown below.
Number of connected slave units
Maximum sink current
and source current of
control output
Ambient temperature
When
communication
unit is connected
1 to 7 units
1 to 6 units
20 mA
-10 to +45ºC
8 to 15 units
7 to 14 units
10 mA
(Note 4)
Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling).
Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
(Note 5)
Do not use or store this product in environments where ambient air is pressurized to an air pressure
higher than the atmospheric pressure at an altitude of 0 m.
8.1 Specifications
8-4
WUME-HGT-6
Содержание HG-T Series
Страница 2: ... MEMO 2 WUME HGT 6 ...
Страница 28: ... MEMO 2 8 WUME HGT 6 ...
Страница 96: ... MEMO 5 50 WUME HGT 6 ...
Страница 99: ... Note 2 Displayed only during calculation 6 1 Flow of Measurement Data WUME HGT 6 6 3 ...
Страница 128: ... MEMO 6 32 WUME HGT 6 ...
Страница 158: ... No timer OFF 7 2 Advanced Settings 7 30 WUME HGT 6 ...
Страница 177: ...Example Positioning a glass plate Setting method 7 2 Advanced Settings WUME HGT 6 7 49 ...
Страница 218: ...8 2 3 Side View Attachment HG TSV10 Units mm 8 2 Dimension Drawings 8 14 WUME HGT 6 ...
Страница 221: ...10 Troubleshooting 10 1 Troubleshooting 10 2 10 2 Error Messages 10 5 WUME HGT 6 10 1 ...
Страница 228: ...Menu Structure General Function Display Menu Structure General Function Display App 2 WUME HGT 6 ...
Страница 229: ...Menu Structure General Function Display WUME HGT 6 App 3 ...
Страница 230: ...Menu Structure Extended Function Display Menu Structure Extended Function Display App 4 WUME HGT 6 ...
Страница 231: ...Menu Structure Extended Function Display WUME HGT 6 App 5 ...
Страница 232: ... MEMO App 6 WUME HGT 6 ...
Страница 235: ... MEMO WUME HGT 6 ...
Страница 236: ...Panasonic Industrial Devices SUNX Co Ltd 2020 PRINTED IN JAPAN WUME HGT 6 ...