223
8-11. Versions of Programming Tools
Note:
•
*
If the OP 74 function is executed, the program stored in the programmable controller will be deleted.
Item
OP 21 (route number
settings)
OP 72 (password
enabled/disabled
settings)
OP 73 (password
registration function)
OP 74 (password
forcing clear function)
*
OP 91 (program/system
register read/write
function)
OP 92 (system register
read/write function)
OP 99 (EEPROM write
function)
OP 112 (Error
cancellation function)
FP Programmer
(AFP1112)
Available
Only routes 1 to 3 can
be selected.
Not available
Not available
Not available
Not available
Not available
Available.
However, “BCC ERR” is
displayed on the LCD if
a program with more
than 11 k steps is written
to EEPROM.
Not available
FP Programmer
(AFP1112A)
Available
Routes 1 to 6 can be
selected.
Available
Not available
Not available
Not available
Not available
Available
Not available
FP Programmer
II
(AFP1114)
Available
Routes 1 to 6 can be
selected.
Available
Available
Available
Available
Available
Available
Available