214
8-9. Table of Instructions
• For more about the instructions above, refer to “FP-M /FP1 Programming Manual”.
Word compare:
Start smaller
Word compare:
AND smaller
Word compare:
OR smaller
Word compare:
Start equal or smaller
Word compare:
AND equal or smaller
Word compare:
OR equal or smaller
Double word compare:
Start equal
Double word compare:
AND equal
Double word compare:
OR equal
Double word compare:
Start equal not
Double word compare:
AND equal not
Double word compare:
OR equal not
Double word compare:
Start larger
Double word compare:
AND larger
Double word compare:
OR larger
Double word compare:
Start equal or larger
Double word compare:
AND equal or larger
Double word compare:
OR equal or larger
Double word compare:
Start smaller
Double word compare:
AND smaller
Double word compare:
OR smaller
Double word compare:
Start equal or smaller
Double word compare:
AND equal or smaller
Double word compare:
OR equal or smaller
ST <
AN <
OR <
ST <=
AN <=
OR <=
STD =
AND =
ORD =
STD <>
AND <>
ORD <>
STD >
AND >
ORD >
STD >=
AND >=
ORD >=
STD <
AND <
ORD <
STD <=
AND <=
ORD <=
5
5
5
5
5
5
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
S1, S2
Name
Boolean
Description
Step
Operand
Performs Start, AND or OR operation by comparing two word
data in the following conditions.
ON: when S1 < S2
OFF: when S1
S2
Performs Start, AND or OR operation by comparing two word
data in the following conditions.
ON: when S1
S2
OFF: when S1 > S2
Performs Start, AND or OR operation by comparing two double
word data in the following conditions.
ON: when (S1+1, S1) = (S2+1, S2)
OFF: when (S1+1, S1)
≠
(S2+1, S2)
Performs Start, AND or OR operation by comparing two double
word data in the following conditions.
ON: when (S1+1, S1)
≠
(S2+1, S2)
OFF: when (S1+1, S1) = (S2+1, S2)
Performs Start, AND or OR operation by comparing two double
word data in the following conditions.
ON: when (S1+1, S1) > (S2+1, S2)
OFF: when (S1+1, S1)
(S2+1, S2)
Performs Start, AND or OR operation by comparing two double
word data in the following conditions.
ON: when (S1+1, S1)
(S2+1, S2)
OFF: when (S1+1, S1) < (S2+1, S2)
Performs Start, AND or OR operation by comparing two double
word data in the following conditions.
ON: when (S1+1, S1) < (S2+1, S2)
OFF: when (S1+1, S1)
(S2+1, S2)
Performs Start, AND or OR operation by comparing two double
word data in the following conditions.
ON: when (S1+1, S1)
(S2+1, S2)
OFF: when (S1+1, S1) > (S2+1, S2)
Содержание FP-M Hardware
Страница 1: ...FP M Hardware ACG M0045 1 94 12 FP M Hardware PROGRAMMABLE CONTROLLER ...
Страница 44: ...36 ...
Страница 118: ...110 ...
Страница 266: ...258 RECORD OF CHANGES ACG No Date Description of Changes ACG M0045 1 DEC 1994 First edition RECORD OF CHANGES ...
Страница 267: ......
Страница 268: ......