EYFR03 User Manual
90 of 110
v1.6.0
Chapter 7: EtherNet/IPTM
20 January 2020
Max Angle
CHAR[5]
ASCII digits representing the value. Not used by the EYFR03.
Units
CHAR
Character representing the units of the torque. Not used by the EYFR03 .
Reserved
USINT
Total size: 40 bytes
151
This connection point corresponds to the mask 1 of the EIP network card for the EYFR01.
Name
Data Type
Description
Parameter
USINT
Selects a parameter for the EYFR03 to run. May be any value in the ranges
0-7, ‘0’-‘7’, ‘A’-‘H’ (see above for details). Values outside these ranges
will cause the current parameter to be stopped and leave no parameter
running.
Batch Reset
USINT
When this value changes, the batch will be reset.
Suspend
BOOL
When true, suspends the EYFR03.
Batch
USINT
The number of tightenings to run per batch for the selected parameter.
Ignored if 0.
Total size: 4 bytes
Input Connection Points for Backwards Compatibility
The connection points in this group correspond to the default masks provided in the
EtherNet/IP
TM
network card for the EYFR01 and are provided to make the EYFR03 easier to
drop into existing installations. These connection points are not recommended for new
installations.
100
This connection point corresponds to the default mask of the EIP network card for the EYFR01.
Name
Data Type
Description
Parameter
CHAR
‘A’-‘H’
Tool Type
CHAR[3]
Type of the tool for the current parameter. One of:
“AIR” – Pneumatic air tools
“BAT” – Battery operated tool
“CLK” – Click wrench
“DIG” – Digital torque wrench
“ “ – No parameter running
Parameter Name
CHAR[8]
Name of the parameter
Tightening Status
CHAR
Status of the last tightening. One of:
‘O’ – Good tightening
‘N’ – Bad tightening or no tightening performed since the last parameter
change
Tightening Type
CHAR
Type of the last tightening. One of:
‘B’ – Good tightening that finished a batch
‘C’ – Good tightening that did not finish a batch
‘R’ – Bad tightening
‘N’ – No tightening performed since the last parameter change
Count
USINT
The count of the last tightening.
Batch
USINT
The batch size of the last tightening
Rolling Count
UINT
Number of tightenings that have occurred.
Total
UINT
Number of batches completed in the parameter.
Time
CHAR[6]
ASCII digits of time of last tightening in HHMMSS format.
Date
CHAR[6]
ASCII digits of date of last tightening in MMDDYY format.
Содержание EYFR03
Страница 1: ...EYFR03 User Manual v1 6 0 20 January 2020 ...
Страница 4: ...EYFR03 User Manual 4 of 110 v1 6 0 Quick Start 20 January 2020 Quick Start ...
Страница 8: ...EYFR03 User Manual 8 of 110 v1 6 0 Chapter 1 Overview 20 January 2020 Chapter 1 Overview ...
Страница 47: ...EYFR03 User Manual 47 of 110 v1 6 0 Chapter 4 20 January 2020 Chapter 4 Serial Communications ...
Страница 55: ...EYFR03 User Manual 55 of 110 v1 6 0 Chapter 5 Discrete I O 20 January 2020 Chapter 5 Discrete I O ...
Страница 58: ...EYFR03 User Manual 58 of 110 v1 6 0 Chapter 5 Discrete I O 20 January 2020 ...
Страница 74: ...EYFR03 User Manual 74 of 110 v1 6 0 Chapter 7 EtherNet IPTM 20 January 2020 Chapter 7 EtherNet IPTM ...
Страница 92: ...EYFR03 User Manual 92 of 110 v1 6 0 Chapter 7 EtherNet IPTM 20 January 2020 Total size 4 bytes ...
Страница 93: ...EYFR03 User Manual 93 of 110 v1 6 0 Chapter 8 ToolsNet 20 January 2020 Chapter 8 ToolsNet ...
Страница 100: ...EYFR03 User Manual 100 of 110 v1 6 0 20 January 2020 Chapter 10 PROFINET ...
Страница 104: ...EYFR03 User Manual 104 of 110 v1 6 0 Chapter 10 Data Management 20 January 2020 Chapter 10 Data Management ...
Страница 107: ...EYFR03 User Manual 107 of 110 v1 6 0 Chapter 11 Firmware Updates 20 January 2020 Chapter 11 Firmware Updates ...