EYFR03 User Manual
12 of 110
v1.6.0
20 January 2020
batch count for parameters in the group while the group is running. This does not change the
batch size defined in the parameter.
Groups may be run in free or standard (synchronized) mode. In standard mode, all parameters
must complete a full batch before any parameter can begin running a second batch. In free
mode, each parameter in the group can proceed independently of the others and does not require
all parameters to complete their batch before any parameters can run again. This makes free
groups useful in situations where you have limited need to control tool operation but want to
report rundowns from the tools.
Jobs
Jobs are the top level of operation in the EYFR03, made up of multiple parameters or groups that
must all run together in a sequence. The EYFR03 supports 100 jobs with up to 30 steps each.
Unlike groups, a job may have multiple parameters that use the same tool or even the same
parameter or group multiple times. As with groups, you may override the batch count for
parameter steps in the job. You cannot change the batch sizes for groups when run in a job.
A free group cannot be used as a job step, since they do not ever complete.
Run Screen
The Run screen shows which parameters the unit is currently running. Depending on the number
of active parameters, the Run screen will be in one of several modes.
Содержание EYFR03
Страница 1: ...EYFR03 User Manual v1 6 0 20 January 2020 ...
Страница 4: ...EYFR03 User Manual 4 of 110 v1 6 0 Quick Start 20 January 2020 Quick Start ...
Страница 8: ...EYFR03 User Manual 8 of 110 v1 6 0 Chapter 1 Overview 20 January 2020 Chapter 1 Overview ...
Страница 47: ...EYFR03 User Manual 47 of 110 v1 6 0 Chapter 4 20 January 2020 Chapter 4 Serial Communications ...
Страница 55: ...EYFR03 User Manual 55 of 110 v1 6 0 Chapter 5 Discrete I O 20 January 2020 Chapter 5 Discrete I O ...
Страница 58: ...EYFR03 User Manual 58 of 110 v1 6 0 Chapter 5 Discrete I O 20 January 2020 ...
Страница 74: ...EYFR03 User Manual 74 of 110 v1 6 0 Chapter 7 EtherNet IPTM 20 January 2020 Chapter 7 EtherNet IPTM ...
Страница 92: ...EYFR03 User Manual 92 of 110 v1 6 0 Chapter 7 EtherNet IPTM 20 January 2020 Total size 4 bytes ...
Страница 93: ...EYFR03 User Manual 93 of 110 v1 6 0 Chapter 8 ToolsNet 20 January 2020 Chapter 8 ToolsNet ...
Страница 100: ...EYFR03 User Manual 100 of 110 v1 6 0 20 January 2020 Chapter 10 PROFINET ...
Страница 104: ...EYFR03 User Manual 104 of 110 v1 6 0 Chapter 10 Data Management 20 January 2020 Chapter 10 Data Management ...
Страница 107: ...EYFR03 User Manual 107 of 110 v1 6 0 Chapter 11 Firmware Updates 20 January 2020 Chapter 11 Firmware Updates ...