Chapter 3: Configuring the unit
20 January 2020
year-month-day hour:minute:second
This field must be updated manually when the tool is calibrated and is for informational purposes
only. The date can be set to the current time in the qualifier by selecting
Set Now
at the end of
the Last Calibration row and pressing the ENT key.
Next Calibration
This field is used to store the date at which the tool should be recalibrated. The display order of
this field is:
year-month-day hour:minute:second
This field must be updated manually when the tool is calibrated. The date can be set to the
current time in the qualifier by selecting
Set Now
at the end of the Next Calibration row and
pressing the ENT key. This can be helpful when the recalibration period is a full month or year
because you will only need to update the year or month.
Cycles
This field tracks the total number of cycles performed by the tool since it was learned to the box.
This cycle count is incremented for both accepted and rejected cycles.
This field cannot be edited. If the tool is forgotten and relearned, the cycle count will restart at 0.
Last PM at
This field stores the cycle count at which the tool last received preventative maintenance. This
field must be updated manually when the tool is serviced. The count can be set to the current
cycle count by selecting
Set Now
at the end of the row and pressing the ENT key.
Cycles before PM
Range: 0 to 4,294,967,295
This field indicates the number of cycles between preventative maintenance for the tool. If this
field is set to 0, no tracking of cycle counts for preventative maintenance is performed.
Maint Interval
Range: 0 to 99
This field indicates the maintenance interval in hours of run time for AccuPulse tools. Setting
this field to 0 disables the maintenance interval setting in the tool.
This field is not available for OK/NOK tools.
Accept Input/Reject Input
These fields indicate which inputs were defined as the inputs for the tool. An input tool must
have an Accept Input to be used but may be used without a Reject Input. See the chapter on
Discrete I/O for more information about how these are configured.
These fields are only listed for input tools and cannot be edited.
Содержание EYFR03
Страница 1: ...EYFR03 User Manual v1 6 0 20 January 2020 ...
Страница 4: ...EYFR03 User Manual 4 of 110 v1 6 0 Quick Start 20 January 2020 Quick Start ...
Страница 8: ...EYFR03 User Manual 8 of 110 v1 6 0 Chapter 1 Overview 20 January 2020 Chapter 1 Overview ...
Страница 47: ...EYFR03 User Manual 47 of 110 v1 6 0 Chapter 4 20 January 2020 Chapter 4 Serial Communications ...
Страница 55: ...EYFR03 User Manual 55 of 110 v1 6 0 Chapter 5 Discrete I O 20 January 2020 Chapter 5 Discrete I O ...
Страница 58: ...EYFR03 User Manual 58 of 110 v1 6 0 Chapter 5 Discrete I O 20 January 2020 ...
Страница 74: ...EYFR03 User Manual 74 of 110 v1 6 0 Chapter 7 EtherNet IPTM 20 January 2020 Chapter 7 EtherNet IPTM ...
Страница 92: ...EYFR03 User Manual 92 of 110 v1 6 0 Chapter 7 EtherNet IPTM 20 January 2020 Total size 4 bytes ...
Страница 93: ...EYFR03 User Manual 93 of 110 v1 6 0 Chapter 8 ToolsNet 20 January 2020 Chapter 8 ToolsNet ...
Страница 100: ...EYFR03 User Manual 100 of 110 v1 6 0 20 January 2020 Chapter 10 PROFINET ...
Страница 104: ...EYFR03 User Manual 104 of 110 v1 6 0 Chapter 10 Data Management 20 January 2020 Chapter 10 Data Management ...
Страница 107: ...EYFR03 User Manual 107 of 110 v1 6 0 Chapter 11 Firmware Updates 20 January 2020 Chapter 11 Firmware Updates ...