Chapter 3 Troubleshooting
004-358 ESS-IOT COMMUNICATION FAILURE
Description
Communication failure between the ESS and IOT.
BSD on : CH3.1A CH3.6A
Procedure
Perform re-installation of the software (latest version).
Check the connection status of the MCU MF PWB and ESS
PWB connectors. If no problems are found, replace the MCU
PWB (PL13.1). If the problem persists, replace the ESS
PWB.(PL13.1)
004-361 DRUM MOTOR DRIVE FAILURE
Description
Revolution failure of the DRUM MOTOR.
BSD on : CH9.1 CH9.31A
Procedure
Remove the DRUM ASSY (Y/M/C) and run
DC330
[004-003].
Is the DRUM MOTOR rotating?
Y
N
Is +5 VDC measured between the DRUM MOTOR J210-4
(+) and GND (-)?
Y
N
Check the +5 VDC circuit to the DRUM MOTOR
J210-4 by referring to Chapter 4 Wiring Data.
(WN4.3.9 +5 VRET-1) (WN4.3.10 +5 VRET-2)
(WN4.3.11 +5 VRET-3) (WN4.3.12 +5 VRET-4)
Is +24 VDC measured between the DRUM MOTOR J210-
6 (+) and GND (-)?
Y
N
Check the +24 VDC circuit to the DRUM MOTOR
J210-6 by referring to Chapter 4 Wiring Data.
(WN4.3.13 +24 VDC-1) (WN4.3.14 +24 VDC-2)
(WN4.3.15 +24 VDC-3) (WN4.3.16 +24 VDC-4)
Run
DC330
[004-003].
Is 0 VDC measured between the DRUM MOTOR J210-1
(+) and GND (-)?
Y
N
Run
DC330
[004-003].
Is 0 VDC measured between the I/F PWB J535-B5
(+) and GND (-)?
Y
N
Check the wire between the DRUM MOTOR
J210-1 and the I/F PWB J535-B5 for an open
circuit and poor contact. If no problems are
found, replace the MCU PWB.(PL13.1)
Check the wire between the DRUM MOTOR J210-1
and the I/F PWB J535-B5 for an open circuit and poor
contact.
Run
DC330
[004-003].
Is 0 VDC measured between the DRUM MOTOR J210-2
(+) and GND (-)?
Y
N
Run
DC330
[004-003].
Is 0 VDC measured between the I/F PWB J535-B3
(+) and GND (-)?
Y
N
Check the wire between the DRUM MOTOR
J210-2 and the I/F PWB J535-B3 for an open
circuit and poor contact. If no problems are
found, replace the I/F PWB.(PL9.1)
Check the wire between the DRUM MOTOR J210-2
and the I/F PWB J535-B3 for an open circuit and poor
contact.
Run
DC330
[004-003].
Is the frequency between the DRUM MOTOR J210-3 (+)
and GND (-) 1 KHz to 1.3 KHz?
Y
N
Run
DC330
[004-003].
Is the frequency between the I/F PWB J535-B2 (+)
and GND (-) 1 KHz to 1.3 KHz?
Y
N
Check the wire between the DRUM MOTOR
J210-3 and the I/F PWB J535-B2 for a short
circuit to the frame. If no problems are found,
replace the I/F PWB.(PL9.1)
Check the wire between the DRUM MOTOR J210-3
and the I/F PWB J535-B2 for an open circuit and poor
contact.
Replace the DRUM MOTOR.(PL1.1)
Run
DC330
[004-003].
Is +5 VDC measured between the I/F PWB J535-B1 (+) and
GND (-)?
Y
N
Replace the I/F PWB.(PL9.1)
If the problem persists, replace the MCU PWB. (PL13.1)
Run
DC330
[004-003].
Is +5 VDC measured between the DRUM MOTOR J210-8 (+)
and GND (-)?
Y
N
Check the wire between the I/F PWB J535-B1 and the
DRUM MOTOR J210-8 for an open circuit and poor
contact.
Replace the DRUM MOTOR.(PL1.1)
Содержание DP-C321
Страница 4: ...This page is intentionally left blank ...
Страница 5: ...Chapter 1 General ...
Страница 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Страница 23: ...1 17 Chapter 1 General ...
Страница 24: ...Chapter 2 Maintenance ...
Страница 63: ...Chapter 3 Troubleshooting ...
Страница 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Страница 378: ...3 304 Chapter 3 Troubleshooting Read Write Read Write Description Memory Spool 512 KB 32 MB 256 KB interval ...
Страница 445: ...Chapter 4 Parts List ...
Страница 527: ...4 80 Chapter 4 Parts List 17 RACK PL17 1 Rack Ref No Part No Description 7901 17E9471X Rack Caster Front j0mf51901 ...
Страница 548: ......