Chapter 3 Troubleshooting
015-362 X Hard Failure
BSD on : CH6.12A
[Detection Condition]
X Hard Failure
[Actions]
Turn the power On/Off. If the problem persists,
replace the IIT/IPS PWB. (PL16.3)
015-367 X PIO Failure
BSD on : CH6.12A
[Detection Condition]
X PIO Failure
[Actions]
Turn the power On/Off. If the problem persists,
replace the IIT/IPS PWB. (PL16.3).
015-370 X PIO Initialization Failure 1
BSD on : CH6.12A
[Detection Conditions]
When Power On Ack was received from the IISS, and
error of the X Hot Line was detected.
[Actions]
If the problem persists after turning the power On/Off,
perform the following:
(1) Check the connection of the IIT/IPS PWB
Connection Harness.
(2) Replace the ESS PWB. (PL13.1)
(3) Replace the IIT/IPS PWB. (PL16.3)
015-371 X PIO Initialization Failure 2
BSD on : CH6.12A
[Detection Conditions]
When Memory Ready Check [Ready] was received
from the IISS, and error of the X Hot Line was
detected.
[Actions]
If the problem persists after turning the power On/Off,
perform the following:
(1) Check the connection of the IIT/IPS PWB
Connection Harness.
(2) Replace the ESS PWB. (PL13.1)
(3) Replace the IIT/IPS PWB. (PL16.3)
015-372 X PIO Initialization Failure 3
BSD on : CH6.12A
[Detection Conditions]
When Memory Ready Check [End] was received from
the IISS, and error of the X Hot Line was detected.
[Actions]
If the problem persists after turning the power On/Off,
perform the following:
(1) Check the connection of the IIT/IPS PWB
Connection Harness.
(2) Replace the ESS PWB. (PL13.1)
(3) Replace the IIT/IPS PWB. (PL16.3)
015-375 X PIO Before Scan Failure
BSD on : CH6.12A
[Detection Conditions]
An error of the X Hot Line was detected when Scan
Start is sent to the IISS.
[Actions]
If the problem persists after turning the power On/Off,
perform the following:
(1) Check the connection of the IIT/IPS PWB
Connection Harness.
(2) Replace the ESS PWB. (PL13.1)
(3) Replace the IIT/IPS PWB. (PL16.3)
015-376 X PIO Unmatch Failure 1
BSD on : CH6.12A
[Detection Conditions]
When X Job Failure was received from the IISS, an
error of the X Hot Line was detected.
[Actions]
If the problem persists after turning the power On/Off,
perform the following:
(1) Check the connection of the IIT/IPS PWB
Connection Harness.
(2) Replace the ESS PWB. (PL13.1)
(3) Replace the IIT/IPS PWB. (PL16.3)
015-377 X PIO Unmatch Failure 2
BSD on : CH6.12A
[Detection Conditions]
When IIT Image Delivered was received from the
IISS, an error of the X Hot Line was detected.
[Actions]
If the problem persists after turning the power On/Off,
perform the following:
(1) Check the connection of the IIT/IPS PWB
Connection Harness.
(2) Replace the ESS PWB. (PL13.1)
(3) Replace the IIT/IPS PWB. (PL16.3)
015-380 Platen AGC CH1 Failure
BSD on : CH6.12A
[Detection Conditions]
Platen AGC CH1 Failure
[Actions]
Turn the power On/Off.
If the problem persists after turning the power On/Off,
check the connection of the IPS PWB P721 and CCD
Connector D741.
If the problem persists, replace the following
components in sequence:
• IIT/IPS PWB (PL16.3)
• CCD Flat Cable (PL16.4)
• CCD PWB (PL16.4)
Содержание DP-C321
Страница 4: ...This page is intentionally left blank ...
Страница 5: ...Chapter 1 General ...
Страница 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Страница 23: ...1 17 Chapter 1 General ...
Страница 24: ...Chapter 2 Maintenance ...
Страница 63: ...Chapter 3 Troubleshooting ...
Страница 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Страница 378: ...3 304 Chapter 3 Troubleshooting Read Write Read Write Description Memory Spool 512 KB 32 MB 256 KB interval ...
Страница 445: ...Chapter 4 Parts List ...
Страница 527: ...4 80 Chapter 4 Parts List 17 RACK PL17 1 Rack Ref No Part No Description 7901 17E9471X Rack Caster Front j0mf51901 ...
Страница 548: ......